GL MAPS MGCP HD Quick Install Manual Download Page 3

MAPS™ MGCP HD (PKS109) 

Quick Install Guide 

 

 

 

Page 3 

 

 

On PC2, Click 

Call Reception 

icon 

 on both MG1, MG2 and observe the 

RTP_Stats_Display.gls

 script activated in the 

Call Reception window.  

 

On PC1, from 

Emulator-> Load Generation

 from main menu 

 

By default, 

MGCPCallControl-TGW.gls

 script and 

TGWProfie0*

 profiles are loaded.  

 

Total calls to Generate by default is set to ‘*’, (indicates no limit) 

 

Maximum Active calls to 2000.  

 

Fixed statistical distribution pattern  

 

Click 

Start 

button to initiate the bulk call generation.  

 

 

On both the MG1 & MG2 MAPS™ MGCP instances, click 

 icon and open 

Call Reception.

 

 

Observe that the calls are automatically received at the 

Call Reception (MG1 & MG2)

 window running the Rx script. 

 

 

To verify results, invoke 

Statistics

 window from 

Reports

 menu, to view the number of calls passed/failed, which are also 

plotted as pie-graph, Calls per sec graph, and Simultaneous calls per sec graph. Switch to Message Stats tab to view the 
statistics of the messages sent/received related to MGCP protocol. 

 

Observe the RTP packets received on each port of the GL’s HD card logged in the RTP Core console 

 
 

Troubleshoot 

 

“Security Error: Application is not licensed”,

 if you see this error when you run MAPS™ MGCP it indicates a problem with 

either your dongle or license file.

 

 

First verify that the dongle is plugged in and the red light is on 

 

Go to 

C:\Program Files\GL Communications Inc\GLDONGLE

 

 

Run

 appl_list.exe

. Verify that there is a line in the table reading 

PKS124 MAPS™ MGCP 

with the serial number 

you noted above. 

 

 

If the SIP/RTP Core console does not invoke with the MAPS™ TestBed start-up, check for the following: 

 

RTP Soft Core licenses may not be installed for the dongle used. Run

 appl_list.exe 

available in the

 C:\Program 

Files\GL Communications Inc\GLDONGLE 

directory. Verify that there is a line in the table reading 

PKS102 

RTP Soft Core

 with the serial number you noted above. 

 

Verify that the MGC IP Address and RTP IP Address in the testbed parameters are configured with the proper 
system IP address. 

 

 

Verify Physical Connection 

 

Check manually the LEDs on the HD card connected, if the GL’s HD Interface card is located at local system 

 

To verify from remote location, run 

Monitoring.exe

 utility, which displays the link status SFP Type connection and the 

auto negotiated link speed.  

 

Important Column Description: 

P - Port number 
A - Adapter number 

Type - Connection type  
Link - Link speed (Down indicates cable is unplugged or SFP module is incompatible) 

 