1. Battery Installation 

Remove battery compartment cover, install a PP3 9 Volt alkaline battery and 
replace battery compartment cover. 
 

2. Clear Code 

Turn the unit on and clear any existing detector codes by pressing and 
holding the LEARN button for 4 seconds until the TAMPER red LED starts to 
flash, then release the button. The unit is now ready to learn a new detector 
code. 
 

3. Learn Detector Code 

Plug the detector’s code transfer lead in to the LEARN socket in the end of the  
D-TectX Signal Strength / Walk Tester, press and release the detector’s 
Programme Button, press and release the LEARN button. After 2 seconds the 
Tamper, Signal Strength 2 and 4 LEDs will flash 3 times to confirm the code 
has been transferred.  
If this does not show then repeat steps 2 – 3. 
  

4. Signal Strength Testing 

The detector needs to be put in to transmit test mode by pressing the 
Programme Button on the detector 8 times and on the eighth press keep the 
button held until the LED goes off then releas the button. The detector will 
now transmit a signal every 2 seconds for approximately 8 minutes.  This can 