GJD D-TECT Walktester GJD380 Installation & User Manual Download Page 1

D-TECT Walktester

GJD380 Installation Tool

Installation & User Guide

The D-TECT WalkTester (Fig.3) is an installation tool that will help the 

installer set up GJD D-TECT’s on site.

*Each D-TECT external detector has been fitted with and infra-red LED 

emitter. When activation occurs the transmitter sends a signal. This 

signal is then received by the WalkTester and a very bright white LED 

on the WalkTester flashes, also a Piezo speaker sounds.

Under normal situations both the LED and the sounder can be seen 

and heard up to 50 meters.

*Please note that some of the earlier versions of D-TECT’s were not 

fitted with IR transmitters and so the WalkTester will not work with 

these units. To verify please take the cover off the D-TECT and look 

at the **bottom of the circuit board for a blue IR LED (Fig.1). If this 

is present then the WalkTester will be able to communicate with the 

D-TECT.

Fig.1 D-TECT IR emitter

NOTE:

 For D-TECT 2 and 

D-TECT 50 the IR LED is on 

the front of the circuit board. 

On the D-TECT 3 it is on the 

rear PDB.

Fig.2 WalkTester holder & 

bracket

Fig.3 WalkTester

Powering The Walktester

The D-TECT WalkTester comes with a mounting bracket / holder 

(Fig.2).

First fit a PP3 battery into the WalkTester battery compartment (Fig.5 

& Fig.7). This is done by removing the battery compartment cover as 

shown in Fig.4. Please ensure that the on/off switch on the WalkTester 

is set to the ‘off’ position while connecting the battery (Fig.6). When 

fitted close the battery compartment and the WalkTester is ready for 

use (Fig.8).

Fig.4. Removing battery 

compartment cover

Fig.5. PP£ battery connector

Fig.6.6 On / Off switch

Fig.7. PP3 battery fitted

Fig.8. Cover replaced