background image

PACKAGING

• 

1x wireless detector

• 

3x wall plug & screw sets

• 

1x tamper cup

• 

2x tamper caps (different lengths)

• 

1x plastic opening tool

• 

1x installation manual

• 

1x drilling template for fixing holes

• 

1x 5m wide Fresnel lens (Lens2, Fig. 8)

IMPORTANT INFORMATION: 

To fully utilize the GJD 

D-TECT Unit with Texecom Ricochet Monitoring Software, 

please upgrade your monitoring software via the Texecom 

website to the Version 2.18.0 or later.

INTRODUCTION

The wireless detector uses a quad pyro where both sen-

sors must trigger to cause the detector to signal an alarm 

ensuring precise and reliable presence detection. 

Programmable options include a variable pulse count and a 

choice of detection ranges up to 50 meters.

The dual-axis tilt sensor allows 180° of pan and 90°of tilt. 

This increases the speed of the outdoor installation and 

provides accurate aiming of the detection pattern.

Precision electronics, digital white light filtering and double 

shielding eliminates false alarms from the sun.

The detector housing has a professional appearance with 

the sensing module hidden behind the front cover.

QUICK INSTALLATION

1. 

Place two CR123 batteries into the detector battery 

holders. Observe the polarity. See figure 4. The 

detection LED will flash four times.

2. 

With the Ricochet

®

 expander in commission mode 

enter the learning menu on the control panel. To learn 

the device follow the instruction given in the control 

panel documentation.

3. 

Press and release the programming button once 

to learn the device. (Fig 4, item 2).This action also 

activates walk test mode. Note: The learn process 

may take up to 10 seconds from pressing the 

programming button. Learn will be confirmed on the 

control panel.

4. 

The detector will take approximately 3 minutes to 

settle. The detection LED is now enabled for five 

minutes. 

5. 

Mount the detector following the instructions below.

Note: To carry out a walk test the zone mode must be 

programmed to be ‘Always Awake’ and the front cover 

must be fitted and secured.

The default settings are:

• 

Range: 50 meters

• 

Pulse count: 1

D-TECT R Ricochet

GJD850R Ricochet

®

 Enabled Wireless 

FITTING THE DETECTOR

Protect the electronics against water. Trapped moisture can 

affect or damage the unit.

Mounting holes should be sealed from within the detector 

using acrylic (non-silicone based) sealants. Silicone 

sealants must not be used as vapours may corrode the 

electronics and metal parts.

Ensure the detector’s field of view is unobstructed.

MOUNTING THE DETECTOR

1. 

Drill the wall to accept the fixing screws and the 

tamper cup (if used). See Figures 1 and 3. 

A hole-drilling template is provided. 

Notes

• 

Use the tamper cup on uneven surfaces.

• 

The optimum mounting height is 3m. When using 

the standard 10m wide Fresnel lens (Lens1, Fig.7) 

Higher mounting heights will result in reduced 

detection range and the target will have to move a 

greater distance within the field of view before an 

alarm is generated.

• 

Remove the cover assembly using the plastic 

opening tool and by loosening the locking screw. See 

Figure 2.

• 

Screw the unit to the wall. Ensure the tamper pin is 

correctly located and the tamper switch is closed. 

Two different length tamper feet are provided for 

uneven surfaces. The tamper foot is a push-fit see 

Figure 1.

• 

When the detector is aligned, powered and 

programmed:

         - 

Fit the cover.

         - 

Loosely tighten the locking screw.

         - 

Push the two side plastic latches into the base.

         - 

Tighten the locking screw.

WARNING

NYLON WASHERS PROVIDED MUST BE USED WITH 

SCREWS ENSURE CABLE ENTRY AND SCREW HOLES 

ARE SEALED WITH WATER BASED SEALANT

DO NOT USE SILICONE BASED SEALANT

1

Summary of Contents for D-TECT R Ricochet GJD850R

Page 1: ...anel 4 The detector will take approximately 3 minutes to settle The detection LED is now enabled for five minutes 5 Mount the detector following the instructions below Note To carry out a walk test the zone mode must be programmed to be Always Awake and the front cover must be fitted and secured The default settings are Range 50 meters Pulse count 1 D TECT R Ricochet GJD850R Ricochet Enabled Wirel...

Page 2: ...urns off typically 4 seconds 3 Count the number of times the LED flashes to deter mine the current value for that option 4 Press the programming button to select the value number for the new setting E g to change the range to 35m press twice The LED blinks twice to indicate that the new value was set Program settings are stored in non volatile memory Resets 1 Remove the batteries 2 Press and hold ...

Page 3: ...unting height Maximum height 3 m 10m wide lens 2 6m 5m wide lens COMPLIANCE Certifications R TTE This device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Environmental Class IP65 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this ...

Page 4: ...1 2 3 4 5a 6 7 6a 8 5b 3m 50m 5m 2 5m 0 2 5m 5m 77º 29º 21 5º 14º 6 56º 4 2 6m 50m Max 5m Programming button Programming LED 1 2 ...

Page 5: ...Unit 2 Birch Business Park Whittle Lane Heywood Greater Manchester OL10 2SX UK www gjd co uk info gjd co uk 44 0 1706 363 998 ENGINEER NOTES ...

Reviews: