Girard Products GSWH-1M Owner'S Manual Download Page 1

Owner’s Manual

Girard Products LLC, 1361 Calle Avanazado, San Clemente CA 92673 U.S.A
Owner’s Manual Part No. 1GWH9407, REV. 1

CAUTION:

Read and Follow all 
the Safety Rules and 
Instructions before 
operating this Appliance.

Demand Tankless Water Heater   
LP Gas
Power Blower Induced Draft         
Gas Modulation Control

Installation and service must be 
performed by a recommended 
installer, service agency or gas 
supplier.

This water heater is certified for 
installation in Recreation Vehicles 
(RV’s) and is not for use in Marine 
or Space Heating Applications

.

Model: GSWH-1M

REVISION 1

1

P a g e

• Installation

• Operation

• Service and Maintenance

Patent Pending

CSA Approved

Summary of Contents for GSWH-1M

Page 1: ...ankless Water Heater LP Gas Power Blower Induced Draft Gas Modulation Control Installation and service must be performed by a recommended installer service agency or gas supplier This water heater is...

Page 2: ...ven Death WARNING FIRE OR EXPLOSION WARNING These instructions must be followed exactly or a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline...

Page 3: ...es designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle This water heater is NOT designed for Marine or Space Heating applicati...

Page 4: ...IONS FROM ANY WINDOW OR OPENING INTO THE VEHICLE DO NOT INSTALL THE WATER HEATER OR ANY OTHER APPLIANCE WHERE IT CAN VENT INTO AN AREA COVERED BY AN AWNING CANOPY OR ANY OTHER ENCLOSURE Note The water...

Page 5: ...build an appropriate frame using 2 X 2 elements Figure 1 The rough opening for the GSWH 1M should be 12 75 X 12 75 with right angle corners The exterior wall opening must be the same dimensions with...

Page 6: ...2 Use two wrenches to tighten the compression fitting to avoid damaging the unit Use additional caulking if needed to complete a permanent seal of the gas line with the housing 6 P a g e PRODUCT DAMAG...

Page 7: ...ng or butyl tape to the back of the door flange that will contact the RV sidewall around perimeter of the opening 6 Insert the door flange into the water heater housing and press the flange firmly aga...

Page 8: ...ntact the mounting frame 5 Slide the water heater in place into the opening and press the door flange against the sidewall 6 Secure water heater housing unit to the vehicle using No 8 flat head screws...

Page 9: ...nstall the door making sure that 1 The door mounting posts on the door flange are properly aligned with corresponding holes along the door s lower edge If needed carefully re align the posts with plie...

Page 10: ...Electrical Code ANSI NFPA 70 and or the CSA C22 1 Canadian Electrical Code Figure 6 This completes the installation of the Model GSWH 1M water heater Insert exhaust tube through door opening CONSUMER...

Page 11: ...low and the Gas Modulation Control GMC setting The Girard Tankless Water Heater heats water while it is being used i e on demand The output temperature of the water depends on the GMC setting the inle...

Page 12: ...ater 3 Locate and set Gas Modulator Dial GMC to the appropriate setting see fig 5 on page 8 a Normal Weather Set Dial to the middle area b Extreme Cold Weather Set Dial to the extreme right area large...

Page 13: ...the water heater in potentially freezing conditions the model GSWH 1M has a built in thermostat that will start the burner whenever the temperature of the Heat Exchanger falls below 38 F and will aut...

Page 14: ...ng the proper operation of the water heater The model GSWH 1M consists of the following main sub systems and components 1 Water Sub System 1 1 Flow Switch 1 2 Heat Exchanger 1 3 Limit Switch Emergency...

Page 15: ...rranty 4 Open the cover and verify that no debris or extraneous combustible materials are present anywhere especially in the area of the burner and the gas controls remove any item present and wipe cl...

Page 16: ...ires a manual reset by either resetting the thermostatic demand turning off the water flow or turning off the power for a period of 5 seconds and then opening the HOT Water Faucet Flame failure If the...

Page 17: ...17 P a g e Figure 10 WIRING DIAGRAM Figure 9 EXPLODED VIEW OF MODEL GSWH 1M AND MAJOR COMPONENTS IDENTIFICATION...

Page 18: ...Manifold Pressure 10 10 5 WCI Power Input 12VDC 3 amp Water Operating Pressure 125 PSI Max Dimension Width 12 5 Height 12 5 Depth 15 5 Shipping Weight 22 lbs ECO max Temperature 131 F Specifications T...

Page 19: ...epairs made confirm that the service center is a recommended service center for Girard Products LLC Water Heaters DO NOT PAY THE SERVICE CENTER FOR WARRANTY REPAIRS WITHOUT PRIOR APPROVAL FROM GIRARD...

Page 20: ...nental United States Alaska Hawaii and Canada Service Your Girard Tankless Water Heater is manufactured to the highest standards and is designed to provide years of trouble free use but in the event y...

Page 21: ...az propane liquide Tirage induit par soufflerie Commande de modulation de gaz L installation et l entretien doivent tre effectu s par un installateur une agence de service ou un fournisseur de gaz rec...

Page 22: ...E EN GARDE Le non respect de ces instructions peut entra ner un incendie ou une explosion causant des dommages mat riels des blessures ou des d c s Ne pas entreposer ni utiliser d essence ou d autres...

Page 23: ...R sont des v hicules con us comme r sidence temporaire pour les vacances le camping ou les voyages ils peuvent tre autopropuls s ou remorqu s par un autre v hicule Ce chauffe eau N est PAS con u pour...

Page 24: ...EN TRE OU D UNE OUVERTURE DU V HICULE NE PAS INSTALLER LE CHAUFFE EAU OU TOUT AUTRE APPAREIL DANS UN ENDROIT O L VACUATION SE FERAIT DANS UN ESPACE RECOUVERT D UN AUVENT D UN DAIS OU DE TOUTE AUTRE FE...

Page 25: ...es de 2 po x 2 po 5 cm x 5 cm Figure 1 L ouverture brute du mod le GSWH 1M doit mesurer 12 75 po x 12 75 po 32 4 cm x 32 4 cm avec des angles droits L ouverture du mur ext rieur doit avoir les m mes d...

Page 26: ...ent le chauffe eau dans l ouverture et raccorder les conduites d eau chaude et froide aux raccords po NPT appropri s Les raccordements peuvent tre faits l aide d adaptateurs crou tournant PEX filetage...

Page 27: ...re ou du ruban de caoutchouc butyle au dos de la bride de la porte qui sera en contact avec la paroi lat rale du VR autour de l ouverture 6 Ins rer la bride de porte dans le bo tier du chauffe eau et...

Page 28: ...era en contact avec le cadre de montage 5 Glisser le chauffe eau dans l ouverture et presser fermement la bride de porte contre la paroi lat rale 6 Fixer le bo tier du chauffe eau au v hicule en ins r...

Page 29: ...urant que 1 les tiges de montage sur la bride de la porte sont correctement align es avec les trous correspondants le long du rebord inf rieur de la porte Au besoin r aligner d licatement les tiges l...

Page 30: ...re 6 Cela compl te l installation du chauffe eau mod le GSWH 1M Ins rer le tuyau d chappement dans l ouverture de la porte CONSIGNES DE S CURIT POUR LES CONSOMMATEURS Utiliser du gaz propane liquide s...

Page 31: ...maximum de 36 000 BTU et la temp rature d eau entrante augmentera de 20 70 F selon le d bit d eau chaude et le r glage de la commande de modulation de gaz Le chauffe eau sans r servoir de Girard chauf...

Page 32: ...une demande d eau chaude 3 Tourner le bouton de modulation de gaz au r glage appropri voir Figure 5 la page 28 a Temp rature normale R glage au milieu b Temp rature tr s froide R glage droite grande...

Page 33: ...terrupteur marche arr t en position de marche ON chaque fois que des conditions de gel sont probables Cela ne prot gera pas tout le syst me de plomberie du VR Le VR doit tre con u pour une utilisation...

Page 34: ...g e composants lectriques montrant toutes les interconnexions et les couleurs de fils adopt es 3 Figure 11 Diagramme de circuit illustrant la logique de contr le et la fonction de chaque composant lec...

Page 35: ...e fois que l utilisateur ouvre un robinet d eau chaude l eau actionne l interrupteur de d bit qui envoie une demande thermostatique au circuit imprim de l allumage Une fois la demande re ue le circuit...

Page 36: ...le panneau de l utilisateur Si l indicateur DEL est allum ou s il clignote le type de clignotement indiquera le probl me d tect par le panneau de contr le comme suit Allum sans clignoter probl me de c...

Page 37: ...37 P a g e Figure 10 DIAGRAMME DE C BLAGE Figure 9 VUE CLAT E DU MOD LE GSWH 1M ET IDENTIFICATION DES PRINCIPAUX COMPOSANTS...

Page 38: ...ion d entr e 12 VCC 3 A Pression d eau de fonctionnement 125 PSI max Temp rature max de l eau 125 F 52 C Dimension Largeur 12 5 po 31 75 cm hauteur 12 5 po 31 5 cm profondeur 15 5 po 39 cm Poids d exp...

Page 39: ...AYEZ PAS LE CENTRE DE SERVICE POUR DES R PARATIONS SOUS GARANTIE SANS D ABORD OBTENIR L APPROBATION DE GIRARD PRODUCTS LLC DE TELS PAIEMENTS NE SERONT PAS REMBOURS S 5 Les pi ces d fectueuses ou le ch...

Page 40: ...zone continentale des tats Unis de l Alaska d Hawa et du Canada Service Votre chauffe eau sans r servoir de Girard Products est fabriqu selon les normes les plus lev es et con u pour fonctionner sans...

Reviews: