System 3000
Touch top unit
Venetian blind moves in the upper end position direction.
■
Touch surface (4) at the top within 4 seconds for longer than 10 seconds.
After 10 seconds the status indication (5) flashes once at the bottom or the top depending
on the setting.
Night mode is activated: The status indication (5) lights at the bottom.
Night mode is deactivated: The status indication (5) lights at the top.
■
Touch surface (1) for permanent display. Status indication (5) lights at the top.
Touch surface (3) for night mode. Status indication (5) lights at the bottom.
■
Touch surface (4) at the top for longer than 1 second to confirm the selection.
Night mode is activated: The status indication (5) flashes once at the bottom.
Night mode is deactivated: The status indication (5) flashes once at the top.
The current status is shown after the confirmation.
If there is no actuation for 4 seconds during the setting of the night mode, the setting is
cancelled and the old setting is retained.
With switch inserts, the load state changes with some actions.
Reset to default setting
■
Switch off the mains voltage and switch on again.
■
Within the next 2 minutes simultaneously touch surfaces (1) and (3) for longer than
20 seconds.
After 20 seconds all LEDs of the status indication (5) light and are switched off again
within 10 seconds from top to bottom.
■
During this time, release surfaces (1) and (3) and briefly touch them again simultaneously.
All LEDs of the status indication (5) flash for 5 seconds.
The attachment is reset to the default setting.
Venetian blind position is not changed.
Light is switched off.
With switch inserts, the switching state changes with some actions.
In order to cancel the process, do not touch any surfaces whilst the LEDs of the status in-
dication are switched off in succession.
Factory setting of Venetian blind
Travelling time
2 minutes
Ventilation position
100%, blind/shutter completely closed
Slat adjusting time
0 seconds, shutter operation
Status indication
Permanent display
Light factory settings
Brightness value 1
75% brightness
Brightness value 2
50% brightness
Brightness value 3
25% brightness
Status indication
Permanent display