System 3000

speed regulator insert

Figure 2: Clampable conductor cross-section

Connect the device according to the wiring diagram (Figure 1). Observe the clampable
conductor cross-sections (Figure 2).

Install the device in the appliance box.

The motor can be switched by briefly pressing the Test button (1).

Set the minimum speed, see chapter Setting the minimum speed.

Mount the cover.

Reset the overheating protection / short-circuit protection

If the electronic overheating or short-circuit protection has been triggered, disconnect the speed
controller from the mains.

5.2 Commissioning

Setting the minimum speed

 DANGER!

Mortal danger of electric shock.

The following work must be carried out under mains voltage and therefore may only
be carried out by an electrician!

Only use insulated tools for the work! Cover up live parts in the working environ-
ment.

The minimum speed must be set so that the motor does not stop at the lowest speed set-
ting.

Prerequisites: Speed controller is ready for operation and the central plate is not mounted.

Press the button Test (1) until LED (2) lights up.
The current operating state remains the same.

After 45 seconds without an actuation, the LED (2) goes out and the device exits the set-
ting mode. The minimum speed remains unchanged.

Briefly turn the rotary axle (3).
LED (2) flashes. The speed controller sets the highest adjustable minimum speed.

Turn the rotary axle (3) to the left or right to set the minimum speed. While doing so, take
the motor follow-up into account.

Save the setting: Press the Test button (1) for less than 1 second or do not press for
45 seconds.
The LED (2) goes out. Speed controller switches off.

6

Technical data

Rated voltage

AC 230 V~

Mains frequency

50 / 60 Hz

Standby power

< 0.5 W

3 / 5

82404702

01.04.2021

Summary of Contents for System 3000 2460 00

Page 1: ...tion with suitable cover 3 Product characteristics Product characteristics Device is operating in leading edge phase control Operation without neutral conductor possible Switch on via soft start to maximum speed Minimum speed can be saved permanently Connection of extensions possible Electronic short circuit protection with permanent switch off after approx 100 ms Electronic over temperature prote...

Page 2: ...N 1 1 N L 4 2 1 5 6 3 Figure 1 Connection diagram with optional extensions 1 Button Test 2 LED display 3 Rotary axle 4 3 wire rotary extension 5 2 wire extension 6 Push button NO contact The connection of a central extension is not possible Operation without neutral conductor possible Only connect illuminated push buttons if they have a separate N terminal Precondition The maximum motor current Im...

Page 3: ...insulated tools for the work Cover up live parts in the working environ ment The minimum speed must be set so that the motor does not stop at the lowest speed set ting Prerequisites Speed controller is ready for operation and the central plate is not mounted Press the button Test 1 until LED 2 lights up The current operating state remains the same After 45 seconds without an actuation the LED 2 go...

Page 4: ... 1 overheating protection has tripped Reduce the connected load Disconnect the speed controller from the mains by switching off the circuit breaker Let the speed controller cool down for at least 15 minutes Switch on the circuit breaker and speed controller again Cause 2 short circuit protection has tripped Disconnect the speed controller from the mains by switching off the circuit breaker Elimina...

Page 5: ...rsiepen GmbH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 5 5 82404702 01 04 2021 ...

Reviews: