Gira Plus 5981 00 Short Instructions Download Page 2

Fig.

2: PCB connections

Start-up

Carry out the following steps:

1.

Connect 230 V AC input voltage (see fig. 2, 230 V AC).

2.

Connect system devices to the 24 V connection terminal (see
fig. 2). 
Note the energy points section of the system operating
instructions.

Warranty

The warranty is provided in accordance with statutory requirements
via the specialist trade. Please submit or send faulty devices postage
paid together with an error description to your responsible salesper-
son (specialist trade/installation company/electrical specialist trade).
They will forward the devices to the Gira Service Center.

Technical data

Output

v

oltage

in

battery

operation

Important! Danger!

Electric shock if live parts are touched.

Electric shock may lead to death.

Isolate all appropriate circuit breakers and fuses before working on
the device or load. Cover up live parts in the vicinity!

230 V~ AC

L N

d

F1

+24V GND

24 V DC

Input (primary voltage)

Rated voltage:

230 V (+/- 15 %)

Mains frequency:

45 to 65 Hz

Output (secondary voltage)

Output voltage in mains operation:

27.2 V (+/- 0.5 %)

Rated output current:

6 A

Output power:

150 W

Protection class:

I

Protection level:

IP 30

Fuse on the primary side:

T 2.0 A

Fuse on the secondary side:

T 6.3 A

Ambient temperature at 100% load:

-5 ºC to +40 ºC

Dimensions (L x W x H)

Wall installation 5998 00:
DIN rail 5981 00:

245 x 194 x 85 mm
170 x 125 x 65 mm

Weight:

Wall installation 5998 00:
DIN rail 5981 00:

1.85 kg
1.25 kg

499266_EN.fm  Seite 2  Sonntag, 28. August 2011  9:40 21

Reviews: