Giovenzana GSL30 Translation Of The Original Instructions Download Page 1

Strawinskylaan 1105

1077 XX Amsterdam, The Netherlands

1 / 12

Giovenzana International B.V. reserves the right to change the features and data shown in this document at any time and without notice.

This document cannot therefore be considered a contract with third parties.

EN

translation of the original instructions

GSL30

GSL60

MT-GSL-EN / 21.05.2021

Rev. 3

SILICONE LED STRIPS

CONNECTIONS AND ACCESSORIES  . . . . . . . . . . . . . . . . 2

GSLC001 - Cable-profiled  . . . . . . . . . . . . . . . . . . . . . . . . . 2

GSLC002 - Profiled silicone end cap for power  . . . . . . . 2

GSLC003 - Profiled silicone end cap terminations. . . . . 2

GSLC004 - Profiled screw set . . . . . . . . . . . . . . . . . . . . . . 2

GSLC005 - LED strip tensioners (2 pieces) . . . . . . . . . . . 2

GSLC006 - Wall plugs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

GSLC007 - LED sealant  . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

GSLC008 - Profiled connection set  . . . . . . . . . . . . . . . . . 3

GSLC009 - Profiled - profiled. . . . . . . . . . . . . . . . . . . . . . . 3

GSLC010 - Profiled bridge connector  . . . . . . . . . . . . . . . 3

GSLC011 - Profiled T connector . . . . . . . . . . . . . . . . . . . . 3

GSLC012 - Profiled cross connector  . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

General considerations  . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Operazioni preliminari  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Strips connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Power connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Mounting using Giovenzana tensioner  . . . . . . . . . . . . . . 5

Top fixture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Bottom fixture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
FIXING THE WALL PLUGS. . . . . . . . . . . . . . . . . . . . . . . . . 8
TECHNICAL CARACHTERISTICS  . . . . . . . . . . . . . . . . . . . 9

Flexible strips GL30 and GL60  . . . . . . . . . . . . . . . . . . . . . 9

Cables GSLC001 and GSLC009  . . . . . . . . . . . . . . . . . . . 10

Connectors GSLC0010, GSLC011 and GSLC012  . . . . . 11

Before use, read this booklet carefully to 

acquaint yourself with the features of the 

product. This booklet is an integral part of 

the product and therefore must be kept until 

the product is dismissed.
Improper installation or tampering can cause 

serious damage to people and property, 

therefore installation and maintenance must 

be carried out by specialized and authorized 

personnel.
The device is not intended for use in 

environments with a potentially explosive 

atmosphere or in the presence of corrosive 

substances and in salt fog.

Summary of Contents for GSL30

Page 1: ...3 GSLC011 Profiled T connector 3 GSLC012 Profiled cross connector 3 INSTALLATION 4 General considerations 4 Operazioni preliminari 4 Strips connection 4 Power connections 4 Mounting using Giovenzana t...

Page 2: ...GSLC001 Cable profiled GSLC003 Profiled silicone end cap terminations GSLC004 Profiled screw set GSLC005 LED strip tensioners 2 pieces GSLC002 Profiled silicone end cap for power CONNECTIONS AND ACCES...

Page 3: ...set For LED strip mounting Distance between plugs 1 5 m for vertical installation 0 5 m for horizontal installation On request Connects two LED strips at a flexible angle Connects two LED strips in a...

Page 4: ...ualified service technician TO AVOID ELECTRICAL SHOCK and or damage to the system do not handle the components with wet hands Always make sure the LED Cable strip is disconnected from the power source...

Page 5: ...and then 2 2 Insert and tighten the locking cable tie This cable tie will assure the correct position of the strip 2 3 4b 4a 4c ATTENTION Make sure that the length of the remaining strip is enough to...

Page 6: ...is in the desired position remove the cord and proceed to mount it as follows 8 Pass the strip through the insertion areas until the final position is reached as indicated in the drawings on the right...

Page 7: ...e 11 Screw the tensioner on the wall at the desired position using the 6mm diameter hole ATTENTION Make sure that the LED strip is in the right position and tightly close the fixing cable ties ATTENTI...

Page 8: ...able tie in the wall plug head 4 Position the LED strip centering it on the head of the plug 5 Tighten the cable tie to secure the LED strip to the plug ATTENTION Make sure that the distance between p...

Page 9: ...nt market standard UGR 25 UGR 22 UGR 22 Beam angle 120 120 Shaft area 3 5 m 9 2 m Coil 300 m 300 m Cutting points distance 1 5 m 1 m Flexible strips GSL30 and GSL60 VOC free Volatile Organic Compound...

Page 10: ...GSLC009 Voltage 240 V ac 240 V ac Current max 6 A 6 A Protection with accessories GSLC002 and GSLC004 IP 65 IP 65 Operating temperature 40 70 C 40 70 C Connectors 1 2 Standard length 200 mm 100 mm Ca...

Page 11: ...ac 240 V ac 240 V ac Current max 6 A 6 A 6 A Protection with accessories GSLC002 and GSLC004 IP 65 IP 65 IP 65 Operating temperature 40 70 C 40 70 C 40 70 C Connectable connectors 2 3 4 Connectors GSL...

Page 12: ......

Reviews: