Body and Interior
47
Electrical Switch Adjustment
Adjust any electrical switches which contact the teeter plate for a minimum of .015" of overtravel (the
movement allowed in the switch after actuation before the switch lever and plunger bottoms) after actua-
tion. Proximity switches (see Figure 11-21
) should be adjusted to provide a 4mm gap between the switch
and the teeter plate at the closest point in the teeter plate’s travel.
Front Door Maintenance
All bushings and moving parts in the Vapor door mechanism are sealed and/or permanently lubricated
and require no maintenance other than regular inspection and adjustment.
Figure 11-21, Proximity Switch and Teeter Plate