![Gill WindSonic User Manual Download Page 70](http://html.mh-extra.com/html/gill/windsonic/windsonic_user-manual_2227387070.webp)
WindSonic Doc No 1405 PS 0019 Issue 28 November 2019
69
14.6 Gill Output Message Format
a13GillInst 2487 B06 1120012
Under normal no error conditions a typical data output will show:-
0+083+000.02+00<CR><LF> e.g. Unit ID, Direction, Speed, Status Code.
Under error conditions e.g. blocked paths error code 04 the unit will pad the wind data
with 9’s as follows (Gill Fixed Field setting):-.
0+999+999.9+04<CR><LF> e.g. Unit ID, Direction, Speed, Status Code.
14.7 SDI-12 Status Codes
Code
Status
Condition
00
OK
Sufficient samples in average period
01
Axis 1 failed
Insufficient samples in average period on U axis
02
Axis 2 failed
Insufficient samples in average period on V axis
04
Axis 1 and 2
failed
Insufficient samples in average period on both axes
08
NVM error
NVM checksum failed
09
ROM error
ROM checksum failed
51
Measurement
average building
Will be output up to 68 seconds after power up whilst
initialisation and 1 minute averaging calculations take place
when in High Power mode.
Gill WindSonic
Software Version
SDI-12 Unit
Address
SDI-12 Version
Gill Reference
Number.
Gill WindSonic
Serial Number