WindObserver II (WindObserver FC)
Page 25
Issue 2
Doc. No. 1390-PS-0011
June 2007
8.14. Communications settings
Baud rate
Setting
Configuration code
2400
B1
4800
B2
9600
B3
19200
B4
38400
B5
1200
B6
300
B7
If a request is sent to change the Baud rate, before it changes it must be
confirmed by entering
B ENTER
(at the new Baud rate.)
Eg. If set to B3 (9600 baud), to change to B5 (38400 baud), enter
B 5 ENTER
, change host terminal to 38400 baud, and confirm by
entering
B ENTER
.
NOTE: a random echo will be generated after the B5 confirmation
Duplex mode
Setting
Configuration code
Full duplex
E1
Half duplex
E2
Note:- Refer also to Para 8.3 Networking Configuration details.
Data and parity options
Setting
Configuration code
8 bits, no parity, 1 stop bit
F1
8 bits, even parity, 1 stop bit
F2
8 bits, odd parity, 1 stop bit
F3
7 bits, no parity, 1 stop bit
F4
7 bits, even parity, 1 stop bit
F5
7 bits, odd parity, 1 stop bit
F6