5
SERVICE (MAINTENANCE/CHECKING)
5.1
Care/checking to be carried out by the operator
Warning:
Disconnect the installation before carrying out any work on the swing door in-
stallation! Do not remove the covering of the drive mechanism!
5.1.1
Switching off
• Select the MANUAL operating mode by means of the program switch
or
• actuate the EMERGENCY STOP button (option).
5.1.2 Care
• Regularly clean the floor within the area of the door wing.
• Clean the outside of the drive unit covering with a moistened rag.
Warning:
Do not use running water or high-pressure machines for cleaning the area of
the drive mechanism.
Attention:
Do not use any metal brushes or chemical products for cleaning the installation.
5.1.3 Checking
The installation must be checked at regular intervals, at least every 2 months:
• When the door is moved by hand, can you hear any unusual grinding or screeching
noises?
• Check the free access to and identification of the EMERGENCY STOP button (optio
-
nal).
• Has the drive unit covering been correctly fastened?
Attention:
Please contact immediately your after-sales service if you detect a damage or
malfunction that you cannot repair yourself.