Br-EFB Following Error Settings (Text Menus)
This menu is used to manually configure the Following Error settings for each axis.
Following Error Configuration
This menu is accessed by selecting the 'm) more' selection from any other menu or
the '8) Following Error' command on the Manual PID Config.' menu. If the 'address to
test' is off-board, the user will be prompted for an on-board address. The 'n) Next', 'l)
Last)' and 'j) address to test' are all limited to the four on-board addresses. To exit this
menu:
1) Use the 'm) More...' command to save changes and go to any other menu.
2) Hit the <ESCape> key. Changed values will be discarded, and you will be
returned to the previous menu.
3) Hit the <RETURN> key. Changed values will be saved, and you will be
returned to the previous menu.
- Gilderfluke & Co. - Electronic Feedback Card - version 1.00 - copyright 2018 -
Uptime: 99:23:59:59, Serial Address: 123, IP: 192.168.2.113
ADL: Lorenzo (2015-12-25 0744) w/503 channels @ 12 Offset
Show #4 (of 210) Night Mode looping @ 00:19:49.22
DeviceName Following Error Config. for Axis 1
1) Following Error threshold: 5%
2) Soft Error Timeout: 1.00 second(s)
3) Hard Error Timeout: 5.00 second(s)
u) min/max/jog w/keypad
j) address to test: 123
k) testing: none
resolution: 8 Bits
figure: FigureName
output: OutputName
m) More, n) Next, l) Last, i) Info, o) def, p) Play, h) Halt, v) Verify, x) eXit
Command-
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-EFB Manual / May 22, 2018 3:28 PM / page 120 of 142