MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Page 17
Installation Overview
PA0338X00X D-Box Installation
2 – PA0338X00X D-Box Installation
Installation Overview
Wayne D-Box (PA0338X000)
The PA0338X000 D-Box provides an interface between the Gilbarco Passport system and
Wayne CATs and dispensers. The loop to Wayne dispensers is currently set to 34 mA, JP10
installed.
One D-Box supports eight Wayne pump loops (eight dual-sided dispensers for a total of 16
fueling positions) and 16 Wayne CAT (CRIND) pairs.
Figure 2-1: Wayne D-Box (PA0338X000)
Three 1-inch Conduit
Knockouts are
provided at the rear for
Field Wiring
115 VAC Line Cord
(Q11121-01)
230 VAC Line Cord [Q11736-02 (User to
Supply Plug for 230 VAC)]
A PA0306XXXX D-Box may be used to control dedicated pump loops. The T19547 two-wire
Distribution Board must be jumpered for a 34 mA interface (refer to
“Distribution Board (T19547) -
on
).