Major Hardware Components
System Cables
Page 4-40 MDE-3664B TRIND® Start-up, Service, and Parts Manual · June 2013
Hand-held System Cable Connections on The Advantage Series and MPD-3
Dispensers
For all single-sided units, install Dummy Load Connector (R20526-01) on JB on transmitter
PCB and skip all Side B connections.
Note: If power is applied to Card Cage without antenna cables or dummy load connected, the
transmitter board will be damaged.
On Cable
Connect
To
On
R20509-G2 (marked for Side A)
P1/2
J1
Side A Overhead Antenna (low frequency)
PA/B
*JA
Transmitter PCB Q13564
R20509-G2 (unmarked for Side B)
P1/2
J2
Side B Overhead Antenna (low frequency)
PA/B
*JB
Transmitter PCB Q13564
R20519-G1
J182
P182
Light/Micro Reader PCB Assembly T20182 on Side A Options Door
P7
*J7
DCB PCB Q13563
R20519-G2
J182
P182
Light/Micro Reader PCB Assembly T20182 on Side B Options Door
P8
*J8
DCB PCB Q13563
R20521-G1
J180
P180
Light/Micro Reader PCB Assembly T20182 on Side A Options Door
J177
*P177
Power Supply PCB T20138
GRD
*Ground
stud
Card Cage
R20521-G2
J180
P180
Light/Micro Reader PCB Assembly T20182 on Side B Options Door
J176
*P176
Power Supply PCB T20138
GRD
*Ground
stud
Card Cage
Q13578-01 -01 (marked for Side A) P1
J1
Side A Overhead Antenna (HF)
P1
*J2B
Receive PCB
Q13578-01 (unmarked for Side B)
P1
J2
Side B Overhead Antenna (HF)
P1
*J2A
Receive PCB
R20437-G01
J250
*P250
TI Gateway PCB T20128-G1
J258A
P258
Side A CRIND Logic PCB T17764
J258B
P258
Side B CRIND Logic PCB T17764
R20580-G1 (per unit)
3 prong F
3 prong M
Card Cage, Rear
Notes:
1. *Indicates connection point is on Card Cage assembly.
2. Route R20521-G1, R20521-G2, and R20437-G01 Cables through bottom of Card Cage to Side B for connections.
3. Check whether brand panel lighting ballast is connected to power supply. If so, disconnect ballast from power supply and terminate wires
ends according to NFPA 70, the National Electric Code and applicable local codes.