Important Safety Information

Page 4

MDE-3116E Distribution Box PA0306 Installation Instructions · November 2015

Important Safety Information

Notes: 1) Save this Important Safety Information section 

in a readily accessible location.

2) Although DEF is non-flammable, Diesel is 

flammable. Therefore, for DEF cabinets that are 
attached to Diesel dispensers, follow all the 
notes in this section that pertain to flammable 
fuels.

This section introduces the hazards and safety precautions 
associated with installing, inspecting, maintaining, or servicing 
this product. Before performing any task on this product, read 
this safety information and the applicable sections in this 
manual, where additional hazards and safety precautions for 
your task will be found. Fire, explosion, electrical shock, or 
pressure release could occur and cause death or serious injury, 
if these safe service procedures are not followed. 

Preliminary Precautions

You are working in a potentially dangerous environment of 
flammable fuels, vapors, and high voltage or pressures. Only 
trained or authorized individuals knowledgeable in the related 
procedures should install, inspect, maintain, or service this 
equipment

.

Emergency Total Electrical Shut-Off

The first and most important information you must know is how 
to stop all fuel flow to the pump/dispenser and island. Locate 
the switch or circuit breakers that shut off all power to all fueling 
equipment, dispensing devices, and Submerged Turbine 
Pumps (STPs). 

 

Total Electrical Shut-Off Before Access

Any procedure that requires access to electrical components or 
the electronics of the dispenser requires total electrical shut off 
of that unit. Understand the function and location of this switch 
or circuit breaker before inspecting, installing, maintaining, or 
servicing Gilbarco equipment.

Evacuating, Barricading, and Shutting Off

Any procedure that requires access to the pump/dispenser or 
STPs requires the following actions:

• An evacuation of all unauthorized persons and vehicles 

from the work area 

• Use of safety tape, cones, or barricades at the affected 

unit(s)

• A total electrical shut-off of the affected unit(s)

Read the Manual

Read, understand, and follow this manual and any other labels 
or related materials supplied with this equipment. If you do not 
understand a procedure, call the Technical Assistance Center 
(TAC) at 1-800-743-7501. It is imperative to your safety and the 
safety of others to understand the procedures before beginning 
work.

Follow the Regulations

Applicable information is available in National Fire Protection 
Association (NFPA) 30A; 

Code for Motor Fuel Dispensing 

Facilities and Repair Garages

, NFPA 70; 

National Electrical 

Code (NEC)

, Occupational Safety and Health Administration 

(OSHA) regulations and federal, state, and local codes. All 
these regulations must be followed. Failure to install, inspect, 
maintain, or service this equipment in accordance with these 
codes, regulations, and standards may lead to legal citations 
with penalties or affect the safe use and operation of the 
equipment.

Replacement Parts

Use only genuine Gilbarco replacement parts and retrofit kits on 
your pump/dispenser. Using parts other than genuine Gilbarco 
replacement parts could create a safety hazard and violate 
local regulations.

Safety Symbols and Warning Words

This section provides important information about warning 
symbols and boxes.

Alert Symbol 

 This safety alert symbol is used in this manual and on 

warning labels to alert you to a precaution which must be 
followed to prevent potential personal safety hazards. Obey 
safety directives that follow this symbol to avoid possible injury 
or death.

Signal Words

These signal words used in this manual and on warning labels 
tell you the seriousness of particular safety hazards. The 
precautions below must be followed to prevent death, injury, or 
damage to the equipment:

DANGER

:

 

Alerts you to a hazard or unsafe practice 

which will result in death or serious injury.

WARNING

: Alerts you to a hazard or unsafe practice 

that could result in death or serious injury. 

CAUTION

 with Alert symbol: Designates a hazard or 

unsafe practice which may result in minor injury.

CAUTION

 without Alert symbol: Designates a hazard or 

unsafe practice which may result in property or 
equipment damage.

Working With Fuels and Electrical Energy

Prevent Explosions and Fires

Fuels and their vapors will explode or burn, if ignited. Spilled or 
leaking fuels cause vapors. Even filling customer tanks will 
cause potentially dangerous vapors in the vicinity of the 
dispenser or island.

DEF is non-flammable. Therefore, explosion and fire safety 
warnings do not apply to DEF lines.

The EMERGENCY STOP, ALL STOP, and 
PUMP STOP buttons at the cashier

s station 

WILL NOT shut off electrical power to the 

pump/dispenser. This means that even if you 
activate these stops, fuel may continue to flow 
uncontrolled. 

You must use the TOTAL ELECTRICAL 

SHUT-OFF in the case of an emergency and not 
the console

s ALL STOP and PUMP STOP or 

similar keys.

!

WARNING

!

!

!

!

Summary of Contents for PA0306

Page 1: ...on IMPORTANT INFORMATION Note Current D Boxes are available only with dual interface boards Early D Boxes were available with single or dual interface boards Intended Users This manual is intended for Gilbarco trained and certified Authorized Service Contractors ASCs Table of Contents Topic Page Introduction 1 Important Safety Information 4 Overview 6 Preliminary Preparation 8 Installing D Box 12 ...

Page 2: ... Assembly Cable MTA Pigtails R19263 G1 4 parts required for installing the PA03061020 D Box Required Reading Read the safety information provided in Important Safety Information on page 4 before you begin installation Read NFPA 30A and NFPA 70 Before installing the equipment read understand and follow The National Electrical Code NFPA 70 The Automotive and Marine Service Code NFPA 30A Any national...

Page 3: ...int of Sale RFI Radio Frequency Interference STP Submersible Turbine Pump TAC Technical Assistance Center TWI Two wire Interface UL Underwriters Laboratories UTP Unshielded Twisted pair VAC Voltage Alternate Current MDE 2530 Pump and Dispenser Installation Manual Footprint and Elevations MDE 2531 Gilbarco Pump and Dispenser Start Up and Service Pump Dispenser Start Up Service Manual MDE 2755 STP C...

Page 4: ...e safety of others to understand the procedures before beginning work Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages NFPA 70 National Electrical Code NEC Occupational Safety and Health Administration OSHA regulations and federal state and local codes All these regulations must ...

Page 5: ...dent for example address front back of building and so on Nature of accident for example possible heart attack run over by car burns and so on Age of victim for example baby teenager middle age elderly Whether or not victim has received first aid for example stopped bleeding by pressure and so on Whether or not a victim has vomited for example if swallowed or inhaled something and so on IMPORTANT ...

Page 6: ...ided to select 30 mA for other non Gilbarco Underwriters Laboratories UL listed dispensers Note Interface cables between the D Box and the console controller are not included with the D Box and must be ordered separately Refer to TWI Current Loop on page 10 for proper length and type of cable required Two pieces each of these cables are supplied with Passport systems The D Box houses the power sup...

Page 7: ...her non Gilbarco UL listed dispensers No mixing of differing current loop equipment on a distribution board is allowed 2 Connect only one dispenser or CRIND to any one data loop channel The wiring distance between the D Box and dispensers is not to exceed 2600 feet 5200 feet of total wire and requires twisted pair stranded 14 American Wire Gauge AWG wire Daisy chaining is not allowed with this uni...

Page 8: ...ation Unpacking Equipment When the equipment arrives at the installation site each unit should be unpacked and inspected for possible shipping damage If damage is evident it must be reported to the carrier Shipping damage is not covered under Gilbarco s warranty policy After visual inspection place the unit back in its shipping carton to prevent undue exposure to the elements and store indoors unt...

Page 9: ...power to the D Box must be a properly installed isolated ground receptacle Hubbell IG5261 or equivalent This type receptacle is easily identified by its bright orange color and by the triangle embossed into the face of the outlet The green grounding screw must be attached to the grounding conductor All electrical wiring must conform to NEC and local wiring codes as well as the criteria in this man...

Page 10: ...ceptacle User to supply proper receptacle to meet local electrical code requirements The receptacle providing power to the PA0306 must be a properly isolated ground receptacle Hubbell IG 5261 or the equivalent The green grounding screw must be attached to the grounding conductor Passport System Use the cables listed in the following table to connect the D Box direct to the two wire loop ports TWI ...

Page 11: ... line 8 pin modular jack receptacle to receptacle coupling Q13241 02 Wall mount single 8 pin modular jack receptacle to field wiring Q13241 05 3 way splitter Note Use 14 AWG stranded or solid wire between wall receptacles Field Wiring Requirements A wiring trough is required in the vicinity of the D Box for terminating the conduit runs from the dispensers Three 1 inch knockouts are provided on the...

Page 12: ...and ensure to allow clearance on the left side to connect the AC cable allow clearance above the D Box so that the cover can be removed mount the D Box within 6 feet of the AC outlet 6 Install the conduit for data wires between the wiring trough and the D Box Pull data wires up into the D Box leaving 16 inches of wire inside the D Box This allows for easy installation of the wiring pigtails 7 Conn...

Page 13: ...0 TP1 TP3 P101 P106 P107 R19262 G1 JP4 JP3 JP2 JP1 JP7 JP6 JP5 JP8 Description Board 1 Jumper Settings Board 2 Jumper Settings 2 boards 1 input 16 loops interface to all TWI consoles controllers JP13A In JP11B In JP12 In JP13B In JP11A In JP12 In 2 boards 2 inputs 8 loops interface to all TWI consoles controllers JP13B In JP11B In JP12 In JP13B In JP11B In JP12 In 2 boards 1 input 16 loops 30 mA f...

Page 14: ...structions November 2015 Figure 4 Field Wiring to MTA Pigtails Cut and strip supplied loops for desired number of field connections Wire Nuts 14 AWG Field Wiring R19263 Pigtail Cable Assembly Note If unused pigtail loops are cut the exposed ends must be capped with wire nuts ...

Page 15: ...he lockout tagout procedures in Important Safety Information on page 4 Accessing Transformer To access the transformer for rewiring proceed as follows 1 Turn off the breaker associated with the dedicated receptacle supplying power to the D Box and lockout tagout 2 Unplug the power cord from the dedicated outlet 3 Unplug the power cord from the D Box 4 Remove the D Box cover 5 Disconnect dispenser ...

Page 16: ...vember 2015 Rewiring Transformer To rewire the transformer proceed as follows 1 Remove the loop back see Figure 5 from the side of the transformer opposite the wiring going to the AC receptacle see Figure 6 Figure 5 Removing Loop back Connection Figure 6 AC Receptacle Wiring To the AC receptacle no modifications needed ...

Page 17: ...n page 16 see Figure 7 Figure 7 Moving Secondary Connection 3 Remove the loop back connection and discard it see Figure 8 Figure 8 Removing Loop back Connection Returning Transformer to Service To return the transformer to service proceeds as follows 1 Reinstall the transformer onto its studs and reassemble the transformer shield and D Box board tray 2 Reinstall the AC power cord to the D Box 3 Pl...

Page 18: ...n Association Phillips is a registered trademark of the Phillips Screw Company UL is a registered trademark of Underwriters Laboratories Inc Appendix Rewiring Transformer for Smaller Sites 5 Apply power by turning on the associated circuit breaker 6 Take voltage readings between the TP1 12UN and TP3 GND pins on each of the boards for wiring connections see Figure 3 on page 13 7 Verify that the vol...

Reviews: