MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page E-1
FlexPay II CRIND Retrofit TRIND Settings
Appendix E: FlexPay II CRIND Retrofit TRIND
Settings
The TRIND utilizes a Gateway PCA (T20678-G3) to route the traffic of microreader
communication with overlapping read fields prior to installation of the FlexPay II Retrofit Kit.
Following the installation of FlexPay II Retrofit Kits:
• The Encore 700/FlexPay II CRIND does not utilize the T20678-GX gateway PCA, but
requires an additional programming of Encore 700 CRIND to ensure proper operation at
instances when the read fields overlap.
• The TRIND may read tags erratically if the CRIND BIOS configuration is not correct.
Note: The Encore S E-CIM/700 S utilize the Light and Inductor Assembly (M06143A00X) and
do not require this setting changed as the read fields do not overlap except in lab
simulators.
For proper operation of TRIND, the “Enable Wireless Sync Option” must be enabled. To
enable the option, proceed as follows:
1
Enter CRIND Diagnostics by swiping the CRIND diagnostics card.
2
Press
1
and
Enter
to access the Main Menu.
3
Press
2
and
Enter
to access the Device Config Menu.
4
Press
4
and
Enter
to access the TRIND Menu.
5
Verify that option 3 shows “Enable Wireless Sync Option”. (If “Disable Wireless Sync
Option” is shown, then the option is already enabled and no further action is necessary.).
6
Press
3
and
Enter
to enable the Enable Wireless Sync Option.
7
Press
Enter
to continue.
Note: Ignore the message stating that this option should only be enabled for lab simulators.
8
Verify that option 3 now shows “Disable Wireless Sync Option”.
9
Press
Cancel
four times then press
2
and
Enter
to exit diagnostics.
10
Perform the same operation on the opposite side of the unit.
11
Test the TRINDs on both sides to confirm proper operation.