77
10.
Code table
10-1
NG Code List
Operation
Code
display
Matter
Basic NG
FFFF
FF00
Emergency stop
Preparation for operation off during operation or START OFF in the
running program.
Before
starting
check,
etc.
0001
Zero offset error
During the zero / double check, zero point output has exceeded the
limit over range.
0002
Magnification error
During the zero / double check, magnification output exceeds the
limit over the range.
0003
Zero offset fluctuation error
Difference in the previous and current output value exceeds the set
over.
0004
Magnification fluctuation error
Difference in the previous and current output value exceeds the set
over.
0033
1.On nut runner
Tightening sampling error
2.On position mode
Return to origin point over time error
0034
Homing operation at the time of incomplete.
Position move command of the X/Y-axis has been issued in the state
of origin return is not yet completed.
SOC.T
0106
Gear checkNG1
In the torque-free monitoring time, angle tightening has reached the
cut angle.
0107
Gear checkNG2
Motor current during rotation exceeds the torque upper limit
equivalent.
※
The torque limit is a current value.
0108
Fitting angle over
It does not reach the fitting torque exceeds the cut angle.
0111
SOC.T torque over
Torque value at the time of arrest has exceeded the upper limit.
0112
SOC.T torque under
0133
SOC.T over time
PRE.T
0207
Pre tightening early tightening NG
It reaches the second speed switching torque between the closed
fast decision angle from the start.
0211
Pre tightening torque over
The torque value at the time of arrest has exceeded the upper limit.
0212
Pre tightening torque under
The torque value at the time of stopping does not reach the lower
limit.
0221
Pre tightening time over
The time when stopped exceeds the maximum.
0222
Pre tightening time under
It does not reach the lower limit time at stop.
0231
Pre tightening angle over
Angle at the time of arrest has exceeded the upper limit.
0232
Pre tightening angle under
Angle at the time of arrest does not reach the lower limit.
0233
Pre tightening over time
0240
Pre tightening area over
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...