73
7-17
(Fn.7)
ID controller connection setting
Number
Matter
No.0
ID controller output content setting
No.1
ID controller output content setting
No.2
Function selection of the Interface unit CH12
No.3
SIO start address setting " set at the 1-7 "
No.-
Save at once all of the data of Fn.12 at the SAVE button.
Please refer to the following about the details of the above-mentioned Fn.7.
No.
Digit
Setting value
Transmission timing
No._0
1
st
digit
0
Data transmission at block judgement output
1
Data transmission at start of next block and input of
judgement reset input
2
Data transmission from command from the upper device
Min.3
Not used
2
nd
digit
0 to 7
Set the digit no. of engine no. transmission (digit no-1)
3
rd
digit
0/1
Setting of with or w/o transmission eith axis no.
0: not to be transmitted
1: to be transmitted
4
th
digit
0/1
Setting yes or no with transmission of each axis judgement
0: not to be transmitted
1: to be transmitted
No._1
1
st
digit
Refer to the
undermentioned
data
Set the digit no. of transmission with torque
2
nd
digit
Set the digit no. of transmission with time
3
rd
digit
Set the digit no. of transmission with angle
4
th
digit
Set the digit no. of transmission with gradient
No._2
1
st
digit
0 to 4
I/F unit selection of ch2 function
0: Operation as printer port
1: Connection of ID controller of standard specification
2: Output of T spec. torque and judgement
3: Output of T spec. judgement
4: Connection with J spec. ID controller Quality control PC
This port is possible with operation
if the number is order than zero.
2
nd
digit
0/1
Set Yes or No with transmission of date and time
0: not to be transmitted
1: to be transmitted
3
rd
digit
0/1
Set Yes or No with transmission of program no.
0: not to be transmitted
1: to be transmitted
4
th
digit
0/1
Set Yes or No with transmission of unit no.
0: No/select gradient 1: Yes/select gradient
2: No/select snag. 3: Yes/select snag
No._3
―
1 to 7
Set address of M-Net station
Set station address of unit 1. Address after 2 is the serial
number following to setting value *1.
No._
-
Save the whole data of Fn.12 in a lump by the SAVE button
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...