65
7-8
X-axis rate setting
It is the basic settings for the X-axis.
(
Number 1 to 30
)
Please set the motor and the moving speed, and the like to be used in the X-axis.
X-axis rate number 28 to 30, number 28 is X/Y-axis Inching. - No. 29 is specified point movement.
- No. 30 is used in the back X.
Number is the number of the case to be set from GSK driver panel (= xx-yy).
Number
(yy)
Matter
Setting
range
Increments
No.00
Acceleration time constant
The acceleration time constant at the time of position movement set in the
rotation angle unit of the motor.
0000-7FFF
10
rpm/s
No.01
Deceleration time constant
The deceleration time constant at the time of position movement set in the
rotation angle unit of the motor.
0000-7FFF
10
rpm/s
No.02
Moving Speed
It set the movement speed at the time of position movement.
0000-9999
1mm/s
No.03
Point ± detection range
When the current coordinate is within the range "X-coordinate ± the set value
of the points", GSK driver determines that the move to the specified point has
been completed.
0000-9999
0.1mm
No.04
Range output
①
lower limit
When the current Y-axis coordinate is within the range of
this setting, the output signal "X range output
①
" will turn
ON.
※
0000-9999
1mm
No.05
Range output
①
upper limit
No.06
Range output
②
lower limit
When the current Y-axis coordinate is within the range of
this setting, the output signal "X range output
②
" will turn
ON.
※
0000-9999
1mm
No.07
Range output
②
upper limit
No.07
Motor revolution amount of movement
It is set something to mili meters move when the motor is rotated 1.
0000-9999
0.001
mm/rev
No.08
Motor model
It is set the model of motor.
(See the motor model list)
0000-7FFF
―
No.09
Source direction of rotation
When the position is increased in the positive direction, and set whether the
motor is turning in any direction.
0000:CW direction as viewed from the rear of the motor
0001:CCW direction as viewed from the rear of the motor
0000 / 0001
―
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...