3.2.1 ISDN External
You configure your system's external ISDN connections in the Physical
Interfaces->ISDN Ports->ISDN External menu.
The access configuration for an external ISDN can be set up for point-to-multipoint (P-MP)
and point-to-point (P-P).
The following variants are possible when connecting to more than one ISDN connection:
• All external ISDN connections are only point-to-multipoint connections (P-MP).
• All external ISDN connections are only point-to-point connections (P-P).
• The external ISDN connections are point-to-multipoint connections (P-MP) and point-
to-point connections (P-P).
3.2.1.1 Working with
Choose the
button to edit an entry.
The menu Physical Interfaces->ISDN Ports->ISDN External->
consists of the follow-
ing fields:
Fields in the Basic Settings menu
Field
Description
Description
Enter a user-defined description of the ISDN interface.
The default value is
3 +
.
Name
Shows the name of the ISDN interface.
Possible values:
•
3A=
: 4 wire (S)
•
A
: Displays the port on the module to which the ISDN con-
nection is connected.
Example:
3A=
= The interface is in Port 1 and is used as an
S connector.
Access Type
Select whether the ISDN interface will be operated as a point-
to-multipoint connection or as a point-to-point connection.
Possible values:
3 Physical Interfaces
Gigaset Communications GmbH
54
hybird 120 Gigaset Edition