background image

HC450

Gigaset

Ba Cover HC450.qxd  30.06.2006  10:50 Uhr  Seite 1

A 3 1 0 0 8 - M1 7 9 9 - R1 0 1 - 2 - 7 6 1 9

Issued by

Gigaset Communications GmbH

Schlavenhorst 66, D-46395 Bocholt

Gigaset Communications GmbH is a trademark licensee of Siemens AG

© Gigaset Communications GmbH 2008

All rights reserved.

Subject to availability. Rights of modifications reserved.

www.gigaset.com

VoIPon   www.voipon.co.uk   [email protected]   Tel: +44 (0)1245 808195   Fax: +44 (0)1245 808299 

Summary of Contents for HC450

Page 1: ...nications GmbH Schlavenhorst 66 D 46395 Bocholt Gigaset Communications GmbH is a trademark licensee of Siemens AG Gigaset Communications GmbH 2008 All rights reserved Subject to availability Rights of modifications reserved www gigaset com VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 2: ... door call to specific handset activation of entry lighting same function as first bell key Gigaset Home Control Gigaset Home Control is a standard that allows you to control u household appliances u lights and blinds u alarm systems u heating and air conditioning systems and u door intercoms such as the Gigaset HC450 from a Gigaset cordless telephone The full functionality of the HC450 door inter...

Page 3: ...l u Its function can also be set identically to the top key or u The entry lighting can be activated when the key is pressed This requires the lighting system to be connected to the HC450 control unit If the bottom doorbell key is being used as a lights key it cannot function as a doorbell key Call diversion If call diversion is activated for the door intercom the door call will then be diverted t...

Page 4: ...rcuit e g the entry lighting can be switched on from the handset and if appli cable via the bottom bell key for between 1 and 90 seconds oralsooperatedinpulsemode The connection to the floating contact 230 V 10 A must be undertaken by a qualified elec trician The illustration below shows the cabling with an existing doorbell before and the cabling following installation of the HC450 door intercom ...

Page 5: ... station 13 Setting functions 13 Operating the Gigaset HC450 door intercom using the handset 18 Incoming call from the door intercom 18 Calling the door intercom from an internal user 18 Operation with automatic call diversion 19 Menu tree 21 Appendix 23 Cleaning 23 Questions and answers 23 Gigaset cordless telephones compatible with the HC450 24 Service Customer Care 24 Authorisation 25 Guarantee...

Page 6: ... or trip over them u The control unit includes a radio module in accordance with the DECT standard The operation of medical appliances may be affected Be aware of the technical conditions in your respective environment e g doctor s surgery u The module must not be installed during a thunderstorm nor should any cable connec tions be plugged in or unplugged as to do so would expose you to the risk o...

Page 7: ...posal and separate collection of your old appliance will help pre vent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment For more detailed information about disposal of your old appliance please con tact your city office waste disposal service or the shop where you purchased the product Note...

Page 8: ...ng u 1 plug in power supply unit u 2 hexagon socket screws for fixing the door intercom to the frame u 1 Allen key for the hexagon socket screws u 2 clamping plugs for connecting the cables to the door intercom u 2 doorbell key covers and nameplates u 2 thermal shrinkage tubes Mounting the HC450 door intercom The HC450 door intercom generally replaces the existing doorbell It is suitable for mount...

Page 9: ...it in the jack with the ETS symbol green jack u Hang the door intercom at the top of the frame 45 degree angle see illus tration on right and lower it against the wall Fix the door intercom using the two enclosed hexagon socket screws Caution If you are using the existing bell cable the doorbell system must be set to zero potential prior to installation Caution Cables must not be connected or disc...

Page 10: ...e nameplate Mounting the HC450 control unit Requirements The following requirements for mounting must be fulfilled u The HC450 control unit contains a DECT radio module This module must be mounted within the base station s radio range typically around 30 m indoors Check the range using the handset before fixing the control unit If a connection from a DECT handset to the DECT base station is possib...

Page 11: ...ns for the HC450 door inter com see p 7 u The control unit must not be installed in a fuse box or metal housing u The control unit must not be installed near air conditioning systems in areas with strong sunlight or in dusty environments u The control unit must be protected from the direct influence of water and chemicals u Areas with strong magnetic fields transformers electric motors high voltag...

Page 12: ...for the doorbell with the ETS terminals in the control unit polarity is not relevant New cabling Connect the 2 core cable of the door inter com to the terminals marked ETS in the control unit see illustration below Con nect the bell transformer bell to the Actu ator terminals in the control unit Caution Cables must not be connected or disconnected during a thunderstorm Doorbell Before After Bell t...

Page 13: ... plug on the right hand side of the control unit Slide the cover back into the main casing Screw the cover into place using the casing screw see diagram p 10 Insert the plug in power supply unit into a socket Caution The entry light may only be installed by a qualified electrician Stranded conductors must not be used for the connection and the insulation on the leads must not be stripped by more t...

Page 14: ...e between the base station and control unit the base station can be disconnected from the telephone net work to do this and or briefly discon nect the control unit from the power supply before commencing registra tion u Following successful registration Intercom will appear in the list of inter nal users This preset name can be changed via the handsets refer to the user guide for the handset Setti...

Page 15: ... displayed It contains the entry Call All and the internal names of all reg istered handsets The current setting is displayed Select an internal user e g Anna and confirm q Anna OK If Call All is set an incoming call from the door intercom will be forwarded to all internal users or s Ringer Tone OK The current setting is displayed q Select the desired ringer tone call melody 1 6 or special GHC mel...

Page 16: ... characters for the external call diversion and press OK The setting is saved a Press and hold return to idle status Activating deactivating automatic call diversion to an external number You can only activate the Automatic Call Diversion function if you have previously entered a diversion destination see p 15 Call up the menu for the settings see p 13 q Diversion OK The current setting is display...

Page 17: ...m You can set how long the handset should ring for an incoming call from the door intercom to an internal user and for a call diversion to an external user The follow ing settings can be selected no int Ringing 10 20 30 or 60 seconds Call up the menu for the settings see p 13 q Timer OK alternatively q Int Door Call OK or q Ext Door Call OK The current setting is displayed r Select the desired tim...

Page 18: ...he settings see p 13 q Volume OK r Select the desired volume for the external loudspeaker 1 9 Save Press the display key continue with a Press and hold return to idle status Note The voice connection between the handset and door intercom is activated during the set ting process This allows you to check the vol ume of the external loudspeaker directly VoIPon www voipon co uk sales voipon co uk Tel ...

Page 19: ...ed or Light Press the display key to switch on the entry lighting a Press the end call key The following features are not available for an incoming call from the door intercom u Conducting a conversation u Calling back from a conversation with the door intercom u Toggling a caller at the door intercom u Conducting a conference call with a user at the door intercom u Diverting or forwarding an inco...

Page 20: ...epting the call or terminating the process 1 Press the 1 key to accept the call Press the hash key to end the call The recorded announcement does not offer the option to open the door how ever this option will be available to you if there is a door opener connected to your door intercom O Press the 9 key to open the door Enter the 4 digit PIN If you enter the PIN correctly you will hear a recorded...

Page 21: ...a recorded announcement will sound again 10 seconds before the con nection is due to be terminated The con nection will be automatically terminated if you do not press the 1 key with approx 5 seconds Terminating the process Press the hash key Note The door intercom automatically disconnects the line after the set time and thereby frees the line again VoIPon www voipon co uk sales voipon co uk Tel ...

Page 22: ...y No Function p 14 As Upper Key Second Door Call Light Low Key Setting Internal Dest Call All p 14 INT 1 INT 6 p 13 Ringer Tone Melody 1 Melody 6 GHC Melody p 14 Language Deutsch p 13 English Francais Italiano Nederlands Dansk Suomi Norsk Svenska Espanol Portugues This setting will only appear if the Second Door Call setting is activated in the Upper Door Key menu not available on all Gigaset phon...

Page 23: ...econd p 16 Door Bell impulse 1 second 3 second p 16 Int Door Call no int Ringing 10 second 60 second p 16 Ext Door Call 30 second 120 second p 16 Ext Call Dur 30 second 120 second p 16 VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 24: ... check the installation of the door opener if necessary adjust No function no keys lighting up No operating current Check the installation check whether the connections at the terminals are in the cor rect connection sequence Door intercom working bell working but not signalling at the mobile phones 1 Control unit is not registered with the base station control unit LED flashing Register the contr...

Page 25: ... can be reached any time from anywhere www gigaset com customercare It provides you with 24 7 support for all our products It also provides a list of FAQs and answers plus user guides and current software updates if available for the product for you to download You will also find frequently asked ques tions and answers in the appendix of this user guide For personal advice on our range of prod uct...

Page 26: ...apply to or extend to services performed by the authorised dealer or the customer themselves e g installation configu ration software downloads User guides and any software supplied on a separate data medium shall be excluded from the Guarantee u The purchase receipt together with the date of purchase shall be required as evidence for invoking the Guarantee Claims under the Guarantee must be submi...

Page 27: ...authorised by Gigaset Communications u This Guarantee shall not apply to or extend to services performed by the authorised dealer or the customer themselves e g installation configu ration software downloads User manuals and any software supplied on a separate data medium shall be excluded from the Guarantee u The purchase receipt together with the date of purchase shall be required as evidence fo...

Page 28: ...s relays Actuator max 30 V 1 A 30 VA Light 230 V max 5 A Maximum conduc tor length between control unit and door intercom without connected door opener 100 m with connected door opener Ø 0 6 mm doorbell cable up to 30 m Ø 0 8 mm doorbell cable up to 50 m Colour Grey Operating temperature 20 C to 55 C Storage tempera ture 25 C to 70 C Transport temperature 25 C to 55 C Dimensions Door station cover...

Page 29: ...rnally 18 changing the display language 13 changing the PIN 14 clamping plug 8 diversion destination 15 duration of the bell 16 external call duration 16 for automatic call diversion using 19 incoming call from the door intercom 18 labelling nameplates 9 mounting 7 operating using the handset 18 range of applications 2 registering with the base station 13 second door call 14 setting the call time ...

Page 30: ...1 P Pack contents 7 PIN 19 system PIN 13 Power supply unit 12 Q Questions and answers 23 R Radio range 9 Range of applications 2 Registration paging key 13 Repeater 10 S Safety precautions 5 Second door call 14 Service 24 Setting the bottom key 14 Starting programming 13 Status away 19 home 19 Supplied items 7 Surface mounting 8 System PIN 13 T Technical data 27 Top doorbell key 14 Transformer 11 ...