![GigaDevice Semiconductor GD32F20 Series User Manual Download Page 93](http://html.mh-extra.com/html/gigadevice-semiconductor/gd32f20-series/gd32f20-series_user-manual_2225801093.webp)
GD32F20x User Manual
93
1000: (CK_SYS / 2) selected
1001: (CK_SYS / 4) selected
1010: (CK_SYS / 8) selected
1011: (CK_SYS / 16) selected
1100: (CK_SYS / 64) selected
1101: (CK_SYS / 128) selected
1110: (CK_SYS / 256) selected
1111: (CK_SYS / 512) selected
3:2
SCSS[1:0]
System clock switch status
Set and reset by hardware to indicate the clock source of system clock.
00: select CK_IRC8M as the CK_SYS source
01: select CK_HXTAL as the CK_SYS source
10: select CK_PLL as the CK_SYS source
11: reserved
1:0
SCS[1:0]
System clock switch
Set by software to select the CK_SYS source. Because the change of CK_SYS
has inherent latency, software should read SCSS to confirm whether the switching
is complete or not. The switch will be forced to IRC8M when leaving Deep-sleep
and Standby mode or HXTAL failure is detected by HXTAL clock monitor when
HXTAL is selected directly or indirectly as the clock source of CK_SYS.
00: select CK_IRC8M as the CK_SYS source
01: select CK_HXTAL as the CK_SYS source
10: select CK_PLL as the CK_SYS source
11: reserved
5.3.3.
Interrupt register (RCU_INT)
Address offset: 0x08
Reset value: 0x0000 0000
This register can be accessed by byte(8-bit),half-word(16-bit) and word(32-bit)
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserved
CKMIC
PLL2
STBIC
PLL1
STBIC
PLL
STBIC
HXTAL
STBIC
IRC8M
STBIC
LXTAL
STBIC
IRC40K
STBIC
w
w
w
w
w
w
w
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reserved
PLL2
STBIE
PLL1
STBIE
PLL
STBIE
HXTAL
STBIE
IRC8M
STBIE
LXTAL
STBIE
IRC40K
STBIE
CKMIF
PLL2
STBIF
PLL1
STBIF
PLL
STBIF
HXTAL
STBIF
IRC8M
STBIF
LXTAL
STBIF
IRC40K
STBIF
rw
rw
rw
rw
rw
rw
rw
r
r
r
r
r
r
r
r
Bits
Fields
Descriptions
31:24
Reserved
Must be kept at reset value
Summary of Contents for GD32F20 Series
Page 191: ...GD32F20x User Manual 191 Bits Fields Descriptions 31 0 TRNDATA 31 0 32 Bit Random data ...
Page 290: ...GD32F20x User Manual 290 conversion is ongoing ...
Page 325: ...GD32F20x User Manual 325 15 0 ALRM 15 0 RTC alarm value low ...
Page 385: ...GD32F20x User Manual 385 ...
Page 523: ...GD32F20x User Manual 523 clears AERR bit by writing 0 to it ...