GD32F10x User Manual
683
changes to 65/50=1.3, the value to be set in the addend register is 2
32
/1.30 = 0xC4EC 4EC4.
If the reference clock drift higher, for example, up to 85MHz, the value addend register must
be 0xA000 0000. Initially, the slave clock frequency is set to Clock Addend Value (0) in the
addend register. This value is calculated as above. In addition to configuring the addend
counter, application also needs to set subsecond increment register to ensure to achieve the
precision of 20ns. The value of the register is to update values of timestamp low 32-bit register
after accumulator register overflow. Because the timestamp low register (bit 0 to 30)
represents the subsecond value of system time, the precision is 10
9
ns/2
31
=0.46ns. So in order
to make the system time accuracy to 20ns, sub second increment register value should be
set to 20/0.46 = 0d43.
Note:
The algorithm described below based on constant delay transferred between master
and slave devices (Master-to-Slave-Delay). Synchronous frequency ratio will be confirmed by
the algorithm after a few Sync cycles.
Algorithm is as follows:
Define the master sends a SYNC message to slave time: MSYNCT (n).
Define the slave local time SLOCALT (n).
Define the master local time MLOCALT (n).
Calculation: MLOCALT (n) = MSYNCT (n) + Master-to-Slave-Delay (n)
Define the master clock count number between two SYNC message sent:
MCLOCKC(n)
Calculation: MCLOCKC (n) = MLOCALT (n)
– MLOCALT (n-1)
Define the slave clock count number between two received SYNC messages: SCLOCKC
(n)
Calculation: SCLOCKC (n) = SLOCALT (n) - SLOCALT (n-1)
Define the difference between these two count numbers: DIFFCC (n)
Calculation: DIFFCC (n) = MCLOCKC (n) - SCLOCKC (n)
Define the slave clock frequency-adjusting factor: SCFAF (n)
Calculation: SCFAF (n) = (MCLOCKC (n) + DIFFCC (n)) / SCLOCKC (n)
Define the Clock Addend Value for addend register: Clock Addend Value (n)
Clock Addend Value (n) = SCFAF (n) * Clock Addend Value (n-1)
Note
: During the actual operation, application may need more than once SYNC message
between master and slave to lock.
System time initialization procedure
Setting TMSEN bit in ENET_PTP_TSCTL register to 1, timestamp function is enabled. Each
time after this bit is set from reset, application must initialize the timestamp counter at first.
Initialization steps as follow:
Summary of Contents for GD32F10 Series
Page 63: ...GD32F10x User Manual 63 programmed during the chip production ...
Page 117: ...GD32F10x User Manual 117 010 1 0 011 0 9 ...
Page 416: ...GD32F10x User Manual 416 shadow register updates every update event ...
Page 427: ...GD32F10x User Manual 427 value ...