GD32F10x User Manual
678
and MSC reception counters will automatically update:
Alignment error.
CRC mismatch(calculated CRC value is different from FSC field value).
Runt frame (frame length is shorter than 64 bytes).
Length error (length field value is different from the actual received data bytes).
Range error (length field value is larger than maximum size of defined in
IEEE802.3,which is 1518 for untagged frame and 1522 for VLAN tagged frame).
Error signal valid on pin MII_RX_ER.
Note:
Only when the discarded frame is a short frame whose length is less than 6 bytes (no
complete receives the DA), MSC reception counter is updated.
22.3.4.
Wake up management: WUM
Ethernet (ENET) module supports two wakeup methods from Deep-sleep mode. The one is
remote wakeup frame and the other is Magic Packet wakeup frame. For reduce power
consuming, the host system and Ethernet can be powered down and thus the circuit driven
by HCLK or transmit clock is stop working. But the circuit driven by receive clock will continues
working for listening wakeup frame. If application sets the PWD bit in ENET_MAC_WUM
register, the Ethernet enters into power-down state. In power-down state, MAC ignores all the
frame data on the interface until the power-down state is exited. For exiting power-down state,
application can choose one of or both of the two methods mentioned above. Setting W FEN
bit in ENET_MAC_WUM register can make Ethernet wakeup if a remote wakeup frame
received and setting MPE bit in ENET_MAC_WUM register can make Ethernet wakeup if a
Magic Packet frame is received. When any type of wakeup frame is present on interface and
corresponding wakeup function is enabled, Ethernet will generate a wakeup interrupt and exit
power-down state at once.
Remote wakeup frame detection
Setting WFEN bit in ENET_MAC_WUM register can enable remote wakeup detection. When
the MAC is in power-down state and remote wakeup function enable bit is set, MAC wakeup
frame filter is active. If the received frame passes the address filter and filter CRC-16 matches
the incoming examined pattern, then MAC identified the received wakeup frame, and then
MAC returns to normal working state. Even if the length of the wakeup frame exceeds 512
bytes, as long as the frame has a correct CRC value, it is still considered to be effective. After
received the remote wakeup frame, the WUFR bit in ENET_MAC_WUM register will be set.
If remote wakeup interrupt is not masked, then a WUM interrupt is generated.
Remote wakeup frame filter register
Wakeup frame filter register is made up of eight different registers but shared the same
register offset address. So the inner pointer points the next filter register when the filter
register address is accessed by writing or reading. Whatever operation, write or read, it is
Summary of Contents for GD32F10 Series
Page 63: ...GD32F10x User Manual 63 programmed during the chip production ...
Page 117: ...GD32F10x User Manual 117 010 1 0 011 0 9 ...
Page 416: ...GD32F10x User Manual 416 shadow register updates every update event ...
Page 427: ...GD32F10x User Manual 427 value ...
Page 518: ...GD32F10x User Manual 518 These bits are not used in SPI mode ...