- 28 -
System Appearance
2-6 Power Supply Unit LED
PSU LED
State
Description
OFF
No AC power to all power supplies
1Hz Green Blinking
AC present / only standby on / Cold redundant mode
2Hz Green Blinking
Power supply firmware updateing mode
Amber
AC cord unplugged or AC power lost; with a second
power supply in parallel still with AC input power
Power supply critical event causing shut down:
failure, OCP, OVP, fan failure and UVP
0.5Hz Amber Blinking
Power supply warning events where the
power supply continues to operate:
high temp, high power, high current and slow fan
Summary of Contents for R283-Z90-AAD1
Page 10: ... 10 This page intentionally left blank ...
Page 43: ... 43 System Hardware Installation 2 2 1 1 3 2 4 5 3 2 4 5 ...
Page 78: ...BIOS Setup 80 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...
Page 90: ...BIOS Setup 92 5 2 8 PCI Subsystem Settings ...
Page 102: ...BIOS Setup 104 5 2 18 Intel R I350 Gigabit Network Connection ...
Page 108: ...BIOS Setup 110 5 3 1 CPU Common Options ...