- 31 -
Hardware Installation
3-4-5 Intel Optane DCPMM DIMM Population Rule
Thermal conditions for DCPMM DIMM support:
• The ambient temperature must be at or below 35°C
• The Cascade Lake CPU used must have a maximum TDP of 205W
• A maximum of 12 pcs 256G DCPMM may be installed
•
RDIMM / DCPMM must be installed into CPU0 memory first
• You must install one RDIMM into any slot #0 of CPU0 before installing the DCPMM.
(e.g. A0/B0/C0/D0/E0/F0)
• The DCPMM must be installed into the DIMM slot #1 next to the corresponding RDIMM
in slot #0 (e.g. if RDIMM is installed into DIMM slot A0, the DCPMM must be installed into
DIMM slot A1)
CPU1
CPU0
DIMM_P0_B
0
DIMM_P0_B
1
DIMM_P0_A0
DIMM_P0_A1
DIMM_P0_D0
DIMM_P0_D1
DIMM_P0_C0
DIMM_P0_C1
DIMM_P0_G1
DIMM_P0_G0
DIMM_P0_H1
DIMM_P0_H0
DIMM_P0_E1
DIMM_P0_E0
DIMM_P0_F1
DIMM_P0_F0
DIMM_P1_L1 DIMM_P1_L0
DIMM_P1_K
1
DIMM_P1_K
0
DIMM_P1_I
1
DIMM_P1_I
0
DIMM_P1_J1 DIMM_P1_J0
DIMM_P1_M
0
DIMM_P1_M
1
DIMM_P1_N0 DIMM_P1_N1
DIMM_P1_P0 DIMM_P1_P1 DIMM_P1_O
0
DIMM_P1_O
1
Summary of Contents for R282-N80
Page 27: ... 27 Hardware Installation 5 1 3 2 4 6 4 3 ...
Page 36: ...Hardware Installation 36 3 9 Cable Routing RAID CARD SAS0 SAS1 RAID CARD ...
Page 37: ... 37 Hardware Installation SAS2 SAS3 ...
Page 38: ...Hardware Installation 38 SAS4 SAS5 ...
Page 39: ... 39 Hardware Installation SAS6 USB Cable ...
Page 40: ...Hardware Installation 40 B P Cable F P Cable ...
Page 41: ... 41 Hardware Installation HDD BP Signal HDD Power ...
Page 69: ... 69 BIOS Setup 5 2 12 Intel R i350 Gigabit Network Connection ...
Page 74: ...BIOS Setup 74 5 3 1 Processor Configuration ...