- 31 -
System Hardware Installation
3-6 Installing the Mezzanine Card
1
2
3
4
Before you install/remove the mezzanine card:
• Make sure the system is not turned on or connected to AC power.
• Disconnect all necessary cable connections. Failure to observe these warnings could result in
personal injury or damage to the equipment.
3-6-1 OCP 3.0
Use of the following type of OCP 3.0 NIC is recommended:
• OCP 3.0 SFF with Pull Tab
• OCP 3.0 SFF with Ejector Latch
Follow these instructions to install an OCP 3.0 mezzanine card:
1. Remove the two screws securing the mezzanine card slot cover.
2. Remove the slot cover from the system.
3.
Insert the OCP 3.0 mezzanine card into the card slot ensuring that the card is firmly connected to
the connector on the motherboard.
4. Tighten the thumbnail screw to secure the OCP 3.0 mezzanine card in place.
5. Reverse steps 3-4 to replace the OCP 3.0 mezzanine card.