Page 1: ...G242 Z10 G242 Z11 AMD EPYC 7002 GPU Server System 4 x GPUs User Manual Rev 1 0 ...

Page 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Page 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...d the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be...

Page 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Page 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Page 7: ... 3 Removing the Heat Sink 26 3 4 Installing the CPU 27 3 5 Installing the Memory 29 3 5 1 Eight Channel Memory Configuration 29 3 5 2 Installing a Memory 30 3 5 3 DIMM Population Table 30 3 6 Installing the PCI Expansion Card 32 3 7 Installing the GPU Card 33 3 8 Installing the Hard Disk Drive 34 3 9 Installing the M 2 Device and Heat Sink G242 Z10 Only 36 3 10 Installing the Mezzanine Card G242 Z...

Page 8: ...on 71 5 2 11 SATA Configuration 72 5 2 12 Network Stack 73 5 2 13 AMD Mem Configuration Status 74 5 2 14 iSCSI Configuration 75 5 2 15 Tls Auth Configuration 76 5 2 16 AVAGO MegaRAID Configuration Utility 77 5 2 17 Intel R I350 Gigabit Network Connection 79 5 2 18 VLAN Configuration 81 5 2 19 MAC IPv4 Network Configuration 83 5 2 20 MAC IPv6 Network Configuration 84 5 3 AMD CBS Menu 85 5 3 1 Valha...

Page 9: ...10 7 Extended memory test point 117 5 10 8 Gnb Earlier init 118 5 10 9 PMU test points 121 5 10 10 ABL0 test points 121 5 10 11 ABL5 test points 121 5 11 Agesa POST Codes 125 5 11 1 Universal Post Code 125 5 11 2 0xA1XX For CZ only memory Postcodes 125 5 11 3 S3 Interface Post Code 128 5 11 4 PMU Post Code 128 5 11 5 0xA5XX assigned for AGESA PSP Module 128 5 11 6 0xA9XX 0xAAXX assigned for AGESA ...

Page 10: ... 10 This page intentionally left blank ...

Page 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Page 12: ...o 128GB supported Memory speed Up to 3200 MHz LAN G242 Z10 2 x 1GbE LAN ports 1 x Intel I350 AM2 1 x 10 100 1000 management LAN G242 Z11 1 x 10 100 1000 management LAN Expansion Slot G242 Z10 4 x PCIe x16 slots Gen3 x16 bus for GPUs Riser Card CRSG027 1 x PCIe x16 slot Gen3 x16 or x8 Low profile half length 1 x PCIe x8 slots Gen3 x0 or x8 Low profile half length 1 x OCP 2 0 mezzanine slot with PCI...

Page 13: ...e 4 x 3 5 SATA hot swappable HDD SSD bays 2 5 HDD SSD supported SATA devices supported only Rear side 2 x 2 5 NVMe SAS SATA hybrid hot swappable HDD SSD bays SAS card is required for SAS devices support SAS Depend on SAS Card Internal I O 1 x TPM header 1 x Front panel header Front I O 1 x USB 3 0 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x NMI button 1 x System status LE...

Page 14: ...tore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings Power Supply 2 x 1600W redundant PSUs 80 PLUS Platinum AC Input 100 120V 12A 50 60Hz 200 240V 10A 50 60Hz DC output Max 1000W 100 120V 12V 81 5A 12Vsb 2 5A Max 1600W 200 240V or 240Vdc Input 12V 133A 12Vsb 2 5A Environment Ambient Temperature Rela...

Page 15: ... 15 Hardware Installation 1 3 System Block Diagram G242 Z10 ...

Page 16: ...G242 Z11 ...

Page 17: ...pter 2 System Appearance 2 1 Front View 1 HDD 0 HDD 1 HDD 2 HDD 3 2 No Description 1 Front Panel LEDs and Buttons 2 Front USB 3 0 Port Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs ...

Page 18: ...0 Port x 2 3 Mezzanine Card Slot OCP 2 0 4 ID LED 5 VGA Port 6 GbE LAN Port 7 10 100 10000 Server Management LAN Port 1 2 3 4 5 6 HDD 4 HDD 5 PSU1 PSU2 No Description 1 Full Height Half Length PCIe Card Slot x 2 2 Mezzanine Card Slot OCP 3 0 3 10 100 10000 Server Management LAN Port 4 VGA Port 5 USB 3 0 Port x 2 6 ID LED G242 Z10 G242 Z11 ...

Page 19: ...n On Indicates locating the HDD Blink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A Off Indicates no HDD access or no HDD error 6 System Status LED Green On Indicates system is operating normally Amber On Indicates a critical condition may include System fan failure System temperature Blink Indicates non critical condition may include Redun...

Page 20: ...Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 2 1 G242 Z10 G242 Z11 1 2 ...

Page 21: ... Blink GREEN Indicates power supply firmware in updating mode Amber Indicates AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Indicates power supply critical event causing shut down failure OCP OVP Fan Fail UVP 0 5Hz Blink Amber Indicates power supply warning events where the power supply continues to operate high temp high power high current slo...

Page 22: ...t LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OFF OFF Rebuilding OFF LED1 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuilding the disk sta...

Page 23: ...ver you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary...

Page 24: ...Follow these instructions to remove the chassis cover 1 Remove the two screws on the sides of the top cover 2 Unlock the plastic handle and pull the grip handle to open the panel cover 3 Slide the cover cover to the rear of the system and then remove the cover in the direction indicated by the arrow 4 To reinstall the chassis cover reverse steps 1 3 Push Li 4 2 3 1 1 ...

Page 25: ...curing the mental fanduct 2 Lift up to remove the fan duct 3 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 1 2 CPU Fan Duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 ...

Page 26: ...the fan duct 1 Loosen the captive screws securing the heatsink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To reinstall the heat sink reverse steps 1 2 while ensuring that you tighten the captive screws in sequential order 1g2g3g4 as seen in the image below 2 4 1 3 ...

Page 27: ...ocedures described in the following sections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in sequential order 1 g 2 g 3 2 Flip open the CPU cover 3 Remove the CPU carrier from the CPU frame using the handle on the CPU carrier 4 Using the handle on the CPU carrier insert the new CPU carrier with C...

Page 28: ...System Hardware Installation 26 CPU 4 5 6 2 3 1 7 ...

Page 29: ...CPU Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be ...

Page 30: ...herboard Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 5 3 DIMM Population Table RDIMM Maximum Frequency Supported Tablle 2R 2 1 DIMMs Populated DIMM 1R 1 1 ...

Page 31: ...d Table 1 2 DIMMs Populated DIMM 2S2R 2S4R 1 2 2933 2666 1 2V Frequency MT s NOTE l 1R 1 package rank of SDP DRAMs l 2R 2 package rank of SDP DRAMs l 2DR 2 package rank of DDP DRAMs l 4DR 4 package rank of DDP DRAMs l 2S2R 2S4R 2S8R 2 package rank of 2 4 8 high 3DS DRAMs l DIMM must be populated in sequential alphabetic order starting with bank A l When only one DIMM is used it must be populated i...

Page 32: ...er assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Loosen the thumbscrew securing the riser bracket to the system 2 Pull the riser bracket in the direction indicated to unlock the riser bracket 3 Remove the screw securing the slot cover to the riser bracket 4 Remove the slot cov...

Page 33: ... the server prior to installing a PCIe card Make sure the system is not turned on or connected to AC power Failure to observe these warnings could result in personal injury or damage to the equipment Follow these instructions to install the GPU card 1 Loosen the thumbnail screw securing the GPU card cage in place 2 Remove the fourscrews securing the GPU card slot bracket and covers in place and re...

Page 34: ... connector on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the 3 5 HDD tray 4 Pull the sides of the HDD tray in the direction indicated 5 Slide the hard disk drive into the HDD tray 6 Push the sides of the HDD tray back in the direction indicated to secure...

Page 35: ...r 3 Pull the locking lever in the direction indicated to remove the 2 5 HDD tray 4 Orient the hard disk drive so the opening on the rear of the hard disk drive is aligned to the positioning stud on the HDD tray 5 Slide the hard disk drive into the HDD tray 6 Reinsert the HDD tray into the slot and close the locking lever Press 1 Pull 2 3 5 4 6 ...

Page 36: ... for 22110 cards as standard Refer to the size of the M 2 device and change the position of the stand off screw accordingly CAUTION CPU TDP is limited to 225W if using M 2 device Follow these instructions to install the M 2 device and heat sink 1 Insert the M 2 device into the M 2 connector 2 Press down on the M 2 device 3 Install the thermal pad of the M 2 device to the M 2 device 4 Press down on...

Page 37: ...ware Installation 3 10 Replacing the Fan Assembly Follow these instructions to replace the fan assembly 1 Lift up the fan assembly from the chassis 2 Reverse the previous steps to install the replacement fan assembly ...

Page 38: ... supply 1 Press the retaining clip on the right side of the power supply along the direction of the arrow 2 Pull up the power supply handle at the same time and pull out the power supply 3 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 1 2 3 ...

Page 39: ... 37 System Hardware Installation 3 12 Cable Routing System Main Power Onboard SATA ...

Page 40: ...System Hardware Installation 38 HDD Backplane Board Signal HDD Backplane Board Power ...

Page 41: ... 39 System Hardware Installation HDD Backplane Board Fan Power Rear HDD Backplane Board Power ...

Page 42: ...System Hardware Installation 40 Front Panel IO Front Panel USB ...

Page 43: ... 41 System Hardware Installation PMBus PS ON Signal ...

Page 44: ...System Hardware Installation 42 NVME Riser Card Power ...

Page 45: ... 43 System Hardware Installation Riser Card SlimLine 8i 1 U2_A0 U2_B0 Riser Card SlimLine 8i 2 U2_A1 U2_B1 ...

Page 46: ...System Hardware Installation 44 Riser Card SlimLine 8i 2 U2_A1 U2_B1 Riser Card SlimLine 8i 4 U2_B1 U2_A1 ...

Page 47: ...AS Connector U2_2B PCIe 14 SlimLine SAS Connector U2_2A PCIe 15 TPM Module Connector SPI Interface 16 SGPIO Connector SGPIO2 17 SlimLine SAS Connector U2_1A PCIe 18 SlimLine SAS Connector U2_1B PCIe 19 Power Connector 20 2 x 12 Pin Power Connector 21 PMBUs Connector 22 Proprietary PCIe x16 Slot Gen3 x16 23 Riser Slot 1 24 OCP Mezzanine Connector OCP 2 0 Gen3 x16 25 Riser Slot 2 26 HDD Back Plane B...

Page 48: ...e x16 Slot Gen4 x16 9 SlimLine SAS Connector U2_2B PCIe 10 SlimLine SAS Connector U2_2A PCIe 11 SGPIO Connector SGPIO1 12 TPM Module Connector SPI Interface 13 SGPIO Connector SGPIO2 14 SlimLine SAS Connector U2_1A PCIe 15 SlimLine SAS Connector U2_1B PCIe 16 Power Connector 17 2 x 12 Pin Power Connector 18 PMBUs Connector 19 Proprietary PCIe x16 Slot Gen4 x16 20 Proprietary PCIe x16 Slot Gen4 x16...

Page 49: ... 21 21 3 Clear CMOS CLR_CMOS Default Enable 3 2 1 NCSI Switch 21 Onboard LAN OCP Mezzanine ON OFF ON Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD J1 1 2 3 Normal Default BIOS recovery mode BIOS_RCVR 4 ...

Page 50: ...0 4 2 2 G242 Z11 Clear CMOS CLR_CMOS Default Enable 3 2 1 21 3 ON Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD J1 1 2 3 Normal Default BIOS recovery mode BIOS_RCVR 4 ...

Page 51: ... caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this chapter ...

Page 52: ... Bridge South Bridge and System event logs Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not t...

Page 53: ... Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup menus described in this chapter are for reference only and may differ by BIOS version Parameter Description BIOS Information Project Name Displays the project name i...

Page 54: ...ry Information Total Memory Note2 Displays the total memory size of the installed memory Memory Frequency Note2 Displays the frequency information of the installed memory System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note1 The number of LAN ports listed will depend on the motherboard system model Note2...

Page 55: ...BIOS Setup 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Page 56: ...nabled to activate TPM support feature Options available Enabled Disabled Default setting is Disabled SPI TPM Support Options available Enabled Disabled Default setting is Enabled Disable Block Sid Options available Enabled Disabled Default setting is Disabled 5 2 1 Trusted Computing ...

Page 57: ... 57 BIOS Setup 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Page 58: ...BIOS Setup 58 5 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Select between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard ...

Page 59: ... 59 BIOS Setup 5 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Serial Port 1 2 Configuration Press Enter for configuration of advanced items ...

Page 60: ...BIOS Setup 60 5 2 4 1 Serial Port 1 2 Configuration ...

Page 61: ...s for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3...

Page 62: ...lt setting is Disabled Wake up year Press and to define the wake up year Wake up month Press and to define the wake up month Wake up Date Press and to define the wake up date Wake up hour Press and to define the wake up hour Wake up minute Press and to define the wake up minute Wake up second Press and to define the wake up second Note This item appears when Wake system from S5 is set to Enabled ...

Page 63: ...f Band Management Windows Emergency Management Services EMS Console Redirection Note Selects a COM port for EMS console redirection EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled COM1 COM2 Serial LAN Legacy Serial Port for Out of Band EMS Console Redirecti...

Page 64: ...acket A start bit indicates the beginning The standard setting is 1 stop bit Communication with slow devices may require more than 1 stop bit Options available 1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can ...

Page 65: ...he CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view the memory information related to CPU 0 ...

Page 66: ...BIOS Setup 66 5 2 7 1 CPU 0 Information ...

Page 67: ...able Auto x16 x8x8 x8x4x4 x4x4x8 x4x4x4x4 Disabled Default setting is Auto MEZZ I O ROM When enabled this setting will initialize the device expansion ROM for the related U 2 device Options available Enabled Disabled Default setting is Enabled Onboard LAN1 LAN2 Controller Note2 Enable Disable the onboard LAN1 LAN2 devices Options available Enabled Disabled Default setting is Enabled Onboard LAN1 L...

Page 68: ... Above 4G Decoding Options available Enabled Disabled Default setting is Enabled SR IOV Support If the system has SR IOV capable PCIe devices this item Enable Disable Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Enabled PCI E AER Enabled Options available Enabled Disabled Default setting is Disabled ...

Page 69: ...etting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support for non USB aware OS Options available Enabled Disabled Default setting is Enabled USB hardware ...

Page 70: ...operly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices Displays the mass storage devices avaiable on the system ...

Page 71: ... 71 BIOS Setup 5 2 10 NVMe Configuration Parameter Description NVMe controller and Drive Information Displays the NVMe devices connected to the system ...

Page 72: ...BIOS Setup 72 5 2 11 SATA Configuration ...

Page 73: ...setting is Enabled Ipv4 HTTP Support Note Enable Disable the Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled IPSEC Certific...

Page 74: ...BIOS Setup 74 5 2 13 AMD Mem Configuration Status Parameter Description CPU0 Press Enter for configuration of advanced items ...

Page 75: ...tion Parameter Description iSCSI Initiator Name Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Page 76: ... Setup 76 5 2 15 Tls Auth Configuration Parameter Description Save CA Configuration Press Enter for configuration of advanced items Client Cert Configuration Press Enter for configuration of advanced items ...

Page 77: ... 77 BIOS Setup 5 2 16 AVAGO MegaRAID Configuration Utility ...

Page 78: ...er for configuration to view Server Profile Action Configure Press Enter for configuration of advanced items Set Factory Defaults Press Enter to active this function Update Firmware Press Enter to active this function Silience Alarm Press Enter to active this function BACKGROUND OPERATIONS in Progress MegaRAID ADVANCED SOFTWARE OPTIONS MegaRAID RAID6 MegaRAID RAID5 MegaRAID FastPath Manage MegaRAI...

Page 79: ... 79 BIOS Setup 5 2 17 Intel R I350 Gigabit Network Connection ...

Page 80: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Page 81: ... 81 BIOS Setup 5 2 18 VLAN Configuration ...

Page 82: ...m 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Enable Disable the VLAN Options available Enable Disable Default setting is Disable Remove VLAN Press Enter to remove an existing VLAN Note Only...

Page 83: ...le DHCP Options available Enabled Disabled Default setting is Enabled Local IP Address Press Enter to configure local IP address Local NetMask Press Enter to configure local NetMask Local Gateway Press Enter to configure local Gateway Local DNS Servers Press Enter to configure local DNS servers Save Changes and Exit Press Enter save all configurations ...

Page 84: ...BIOS Setup 84 5 2 20 MAC IPv6 Network Configuration Parameter Description Enter Configuration Menu Press Enter for configuration of advanced items ...

Page 85: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Page 86: ...e Auto Enabled Disabled Default setting is Auto Power Supply Idle Control Options available Auto Low Current Idle Typical Current Idle Default setting is Auto Opcache Control Options available Auto Enabled Disabled Default setting is Auto SEV ASID Count Options available Auto 253 ASIDs 509 ASIDs Default setting is Auto SEV ES ASID Space Limit Control Options available Auto Manual Default setting i...

Page 87: ...ode Options available Auto Enabled Disabled Default setting is Auto Xtrig7 Workaround Options available Auto No Workaround Bronze Workaround Sliver Workaround Default setting is Auto PPIN Opt in Options available Auto Enabled Disabled Default setting is Auto ...

Page 88: ...lood enabled Default setting is Auto Disable DF sync flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Options available Auto Enabled Disabled Default setting is Auto System probe filter Options available Auto Enabled Di...

Page 89: ...ption DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Page 90: ...he enforce POR DRAM Controller Configuration Press Enter to configure the DRAM controller CAD Bus Configuration Press Enter to configure the cad bus Data Bus Configuration Press Enter to configure the data bus Common RAS Press Enter to configure the common RAS Security Press Enter to configure security ...

Page 91: ...e memory modules When this option sets to Auto it is null No help string Options available Enabled Disabled Auto Default setting is Auto BankGroupSwapAlt Options available Enabled Disabled Auto Default setting is Auto Address Hash Bank Options available Enabled Disabled Auto Default setting is Auto Address Hash CS Options available Enabled Disabled Auto Default setting is Auto Address Hash Rm Opti...

Page 92: ...BIOS Setup 92 5 3 3 3 NVDIMM ...

Page 93: ...ble Interface Mode Data Eye Mode Both Auto Default setting is Auto MBIST Aggressors Note Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter for configuration of advanced items Note This item appears when MBIST Enable is set to Enabled ...

Page 94: ...ble Press Enter for configuration of advanced items SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration of advanced items Enable AER Cap Options available Auto Enabled Disabled Default setting is Auto Early Link Speed Options available Auto Gen1 Gen2 Default setting is Auto Hot Plug Handling mode Options available Auto A0 Mode OS...

Page 95: ...onfiguration of advanced items AC Power Loss Options Press Enter to configure the AC loss control I2C Configuration Options Press Enter for configuration of advanced items Uart Configuration Options Press Enter for configuration of advanced items ESPI Configuration Options Press Enter for configuration of advanced items eMMC Options Press Enter for configuration of advanced items FCH RAS Options P...

Page 96: ...BIOS Setup 96 5 3 6 NTB Common Options Parameter Description NTB Options available Auto Enabled Default setting is Auto ...

Page 97: ...scription ABL Console Out Control Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Page 98: ...u options for configuring the function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description RAS Press Enter for configuration of advanced items SPI Locking Options available Enabled Disabled Default setting is Disabled ...

Page 99: ...CI Default setting is Polled GHES UnCorr Notify Type Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Options available Polled SCI Default setting is Polled PCIe UnCorr GHES Notify Type Options available Polled NMI Default setting is NMI PCIe Root Port Corr Err Mask Reg Initialize the PCIe AER Corrected Error Mask register of Root Port PCIe Root Port UnCorr Err Mask Reg In...

Page 100: ...y Type Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mechanism Options available Enabled D...

Page 101: ...submenu screen Parameter Description PCIe Link Training Type PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items ...

Page 102: ...BIOS Setup 102 5 5 1 North Bridge Parameter Description Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 ...

Page 103: ...tions available Do Nothing Reset Power Down Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note Configure OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default se...

Page 104: ...Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 105: ...sing SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options avail...

Page 106: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Page 107: ...ptions available Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time synch...

Page 108: ...ny BMC network during BIOS phase Options available Enable Disable Default setting is Enable IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 BMC LAN...

Page 109: ...all settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pre...

Page 110: ...rtificates This way the system knows all the files being loaded before Windows loads and gets to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options available Standard Custom Default setting is ...

Page 111: ...ions available Set New Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options ava...

Page 112: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot m...

Page 113: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 114: ... BIOS setup Options available Yes No Save Changes Save changes done so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these...

Page 115: ...ace 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public interface 0xE013 5 10 3 PMU Test Points ABL Mem PMU Before PMU Firmware load 0xE014 ABL Mem PMU After PMU Firmware load 0xE015 ABL Mem PMU Populate SRAM Timing 0xE016 ABL Mem PMU Populate SRAM Config 0xE...

Page 116: ...ABL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Interleave Init 0xE03B ABL Mem ECC initialization 0xE03C ABL Mem Platform Specific Init 0xE03D ABL Mem Before callout for AgesaReadSpd 0xE03E ABL Mem After callout for AgesaReadSpd 0xE03F ABL Mem Before ...

Page 117: ... init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 10 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 10 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0xE081 Sending MRS1 0xE082 Sending MRS0 0xE083 Continuous Pattern Read 0xE084 Continuous Pattern Write 0xE085 Mem 2d RdDqs Training begin 0xE086 Mem Before optional callout to platform BIOS to change...

Page 118: ...ode 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug code 0xE0A6 GNB internal debug code 0xE0A7 GNB internal debug code 0xE0A8 GNB internal debug code 0xE0A9 GNB internal debug code 0xE0AA GNB internal debug code 0xE0AB GNB internal debug code 0xE0AC GNB...

Page 119: ...I Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGMI Initialization Stage 5 Error 0xE6C0 ABL 3 GMI xGMI Initialization Stage 6 0xB6C0 ABL 3 GMI xGMI Initialization Stage 6 Warning 0xF6C0 ABL 3 GMI xGMI Initialization Stage 6 Error 0xE7C0 ABL 3 GMI x...

Page 120: ...n AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allocate a buffer 0xE0E4 Before the heap manager calls out to deallocate a buffer 0xE0E5 After the heap manager calls out to deallocate a buffer 0xE0E6 Before the heap manager calls out to locate a buffe...

Page 121: ... Initialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchronization Function 0xE108 AblbBegin 0xE109 Ab4bBegin 0xE10A BSP encountered HMAC fail on APOB Header 0xE10B ABL Eroor General ASSERT 0xE2A0 Unknown Error 0xE2A1 ABL Error Log Inig Error 0xE2A2 ABL Err...

Page 122: ...r DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for Heap Allocation for PMU SRAM Msg block error 0xE2C3 ABL Error for Heap Phy PLL lock Flure error 0xE2C4 ABL Error for Pmu Training error 0xE2C5 ABL Error for Failure to Load or Verify PMU FW error 0xE2C...

Page 123: ... Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted DIMM Config Error 0xE2F0 ABL Error No Ps Table Error 0xE2F1 ABL Error Cad Bus Timing Not Found Error 0xE2F2 ABL Error Data Bus Timing Not Found Error 0xE2F3 ABL Error LrDIMM IBT Not Found Error 0xE2...

Page 124: ...E30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Error General Assert Error 0xE30F ABL Error No Dimms On Any Channel in sysem 0xE310 ABL Alert PMU Major Message captured 0xE311 ABL Alert PMU REsults Rx Timing captured 0xE312 ABL Alert PMU REsults Tx ...

Page 125: ...A107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTraining 0xA10E TpProcMemSynchronizeDcts 0xA10F TpProcMemSystemMemoryMapping 0xA110 TpProcMemMtrrConfiguration 0xA111 TpProcMemDramTraining 0xA112 Public interface 0xA113 TpProcMemWriteLevelizationTraini...

Page 126: ... Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Channel Interleave Init 0xA13B ECC initialization 0xA13C Platform Specific Init 0xA13D Before callout for AgesaReadSpd 0xA13E After callout for AgesaReadSpd 0xA13F Before optional callout AgesaHookBefore...

Page 127: ...0xA187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For Non Explicit 0xA18B Configure to Sync channels 0xA18C Allocate C6 Storage 0xA18D Before LV DDR4 0xA18E BR CPU BR before AP launch 0xA190 Install AP launched PPI 0xA191 BR after AP launch 0xA192 Befo...

Page 128: ...code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate a buffer 0xA1F5 Before the memory code calls out to locate a buffer 0xA1F6 After the memory code calls out to locate a buffer 0xA1F7 5 11 4 PMU Post Code Failed PMU training 0xA1F9 5 11 5 0xA5XX assig...

Page 129: ...eV2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save area for resume 0xA52F PspSmmV2 SwSmiCallBack exit build the S3 save area for resume 0xA530 PspSmmV2 BspSmmResumeVector entry 0xA531 PspSmmV2 BspSmmResumeVector exit 0xA532 PspSmmV2 ApSmmResumeVector e...

Page 130: ...mand MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mailbox exit base 0xA5DX Cmd 0xA5D0 Wait C2P command MboxBiosCmdDramInfo finished 0xA5D1 Wait C2P command MboxBiosCmdSmmInfo finished 0xA5D2 Wait C2P command MboxBiosCmdSleep SxInfo finished 0xA5D3 Wait...

Page 131: ...it 0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910 AmdSmuV8 PEIM driver exit 0xA911 AmdSmuV8 DXE driver entry 0xA912 AmdSmuV8 DXE driver exit 0xA913 AmdSmuV9 PEIM driver entry 0xA914 AmdSmuV9 PEIM driver exit 0xA915 AmdSmuV9 DXE driver entry 0xA916...

Page 132: ...NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0xA971 PcieConfigurationInit entry 0xA972 PcieConfigurationInit exit 0xA973 GnbEarlierInterfaceCZ entry 0xA974 GnbEarlierInterfaceCZ exit 0xA975 PcieEarlyInterfaceCZ entry 0xA976 PcieEarlyInterfaceCZ e...

Page 133: ...Late exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 11 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX downcore entry 0xAC51 CCX DXE entry 0xAC55 CCX MP service callback entry 0xAC56 CCX Read To Boot callback entry 0xAC57 CCX SMM entry 0xAC5D CCX PEI start to launch APs for S3 0xAC70 CCX PEI end of la...

Page 134: ...ch finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 FCH MultiFch Dxe Entry 0xAF16 FCH MultiFch Dxe Exit 0xAF17 FCH Smm Entry 0xAF18 FCH Smm Exit 0xAF19 FCH Smm Dispatcher Entry 0xAF20 FCH Smm Dispatcher Exit 0xAF21 FCH InitReset HwAcpi 0xAF40 FCH InitR...

Page 135: ...0xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH InitLate HwAcpi 0xAF70 FCH InitLate AB Link 0xAF71 FCH InitLate LPC 0xAF72 FCH InitLate SPI 0xAF73 FCH InitLate eSPI 0xAF74 FCH InitLate SD 0xAF75 FCH InitLate eMMC 0xAF76 FCH InitLate SATA 0xAF77 FCH I...

Page 136: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 12 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Page 137: ...t block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Change xxx ROM to amiboot rom 2 Copy amiboot rom and AFUDOS exe to USB diskette 3 Setting BIOS Recovery jump to enabled status 4 Boot into BIOS recovery 5 Run Proceed with flash update 6 BIOS update ...