Motherboard Components/
主板组件
No.
Code
Description
1 CPU
Intel Xeon® processor D-1541, FCBGA1667 SoC (MB10-DS3)
2
SFP+1_2
SFP+ connectors #1/#2
3
LAN1_2
LAN ports
4
USB3_MLAN
BMC Management LAN port (top) / USB 3.0 ports (bottom)
5
CPU0_FAN
CPU fan connector
6
VGA
VGA port
7
SW_ID
ID switch button w/LED
8
SW_PWR
Power button w/LED
9
LED_STA
System Status LED
10
P12V_AUX1
8 pin power connector
11
FP_1
Front panel header
12
ATX1
24 pin main power connector
13
DIMM_P0_A0
Channel 1 slot 0
14
DIMM_P0_A1
Channel 2 slot 1
15
DIMM_P0_B0
Channel 3 slot 0
16
DIMM_P0_B1
Channel 4 slot 1
17
BAT1
Battery
18
PMBUS
PMBus connector
19
SATA_DOM0
SATA DOM power cable connector
20
SATA0
SATA 3 6Gb/s connector
21
SATA1
SATA 3 6Gb/s connector
22
SATA_2_3
SATA 3 6Gb/s connectors
23
SATA_4_5
SATA 3 6Gb/s connectors
24
SATA_SGPIO
SATA SGPIO header
25
COM1
Serial port cable connector
26
LED_BMC1
BMC firmware readiness LED
27
BP_1
HDD back plane board header
28
NVME_PH
NVME connector
29
TPM
TPM module connector
30
IPMB
IPMB connector
No.
Code
Description
31
CLR_CMOS
Clear CMOS jumper
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear CMOS data.
32
PCIE_1
PCI Express x16 slot
33
ME_UPDATE
ME update jumper
1-2 Close: Normal operation (Default setting)
2-3 Close: ME update mode.
34
ME_RCVR
ME recovry jumper
1-2 Close: Normal operation. (Default setting)
2-3 Close: ME recovery mode.
35
S3_MASK
S3 Power On Select jumper
1-2 Close: Stop an initial power on when BMC is not ready.
2-3 Close: Keep initial power on. (Default setting)
1
3
2
4
5
6
7 8 9
12
10
11
13
14
15
16
19 18
17
20
21
22
23
25
24
26
27
28
30
29
31
32
33
34
35
System Components/
系统组件
No
Description
1
HDD bays
2
System fan #9/#10 (FAN9/FAN10)
3
System fan #7/#8 (FAN7/FAN8)
4
System fan #5/#6 (FAN5/FAN6)
5
System fan #3/#4 (FAN3/FAN4)
6
System fan #1/#2 (FAN1/FAN2)
7
CPU and CPU heat sink
8
Memory slots
9
PCIe riser bracket
10
Power supply cage
CAUTION!
To connect system fan connector, follow the instruction:
Blue/Red cable connect to odd numbered connector.
White/Amber cable connect to even numbered connector.
注意!
蓝/红电缆连连接于单数风扇插座。
白/橘电缆连连接于双数风扇插座。
Front Panel Header/
前面板接头
No.
Pin Define
1
Power LED+
3
No Pin
5
Power LED-
7
HDD LED+
9
HDD LED-
11
Power Button
13
GND
15
Reset
17
GND
19
ID
21
ID Switch-
23
NMI Switch-
No.
Pin Define
2
5V Standby
4
ID LED+
6
ID LED-
8
System Front Board LED+
10
System Status LED-
12
LAN1 Active LED+
14
LAN1 Link LED-
16
SMBus Data
18
SMBus Clock
20
Case Open
22
LAN2 Active LED
24
LAN2 Link LED-
1
2423
2
HDD Back Plane Board Header/
硬盘驱动器底板接头
1 2
25 26
No.
Pin Define
1
BP_SGP_CLK
3
BP_SGP_GLD
5
BP_SGP_DOUT
7
Key Pin
9
GND
11
BP_LED_G_N
13
BP_SGP_DIN
15
GND
17
GND
19
P_3V3_AUX
21
P_3V3_AUX
23
GND
25
BP_PRESENSE
No.
Pin Define
2
No Connect
4
FAN_SGP_Gate
6
GND
8
Reset
10
BP_LED_A_N
12
GND
14
No Connect
16
SMB_BP_DATA
18
SMB_BP_CLK
20
BMC_ACK
22
BMC_REQ
24
Key Pin
26
GND
CAUTION!
Before you remove or install the system
cover:
Make sure the system is not turned on
or connected to AC power.
注意!
在卸下或安装系统机盖之前,请注意
下列事项:
确保系统未开启且未连接到交流电源。
System Cover/
机箱盖
1
1
1
2
3
4
Fan Duct/
风扇散热片
1
2
Memory Population Configuration/
安装内存
Type
Ranks PerDIMM
and
Data Width
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
Speed (MT/s);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel
1DPC
2 Slot Per Channel
1DPC
2DPC
RDIMM
RDIMM
RDIMM
RDIMM
SRx4 ECC
SRx8 ECC
DRx8 ECC
DRx4 ECC
仅Intel Xeon
®
D-1541处理器支持DDR4-MHz内存。
只使用一个DIMM时,必须安装到内存插槽0。
若安装顺序有误,系统将不能正常引导。
Note: DDR4 2400MHz is only available on Intel Xeon® D-1541 processor.
When only one DIMM is used, it must be populated in memory slot0 first.
System will not boot normally with incorrect populated sequence.
System Fan/
系统风扇
CAUTION!
Before you remove or install the system fan:
Make sure the system is not turned on or
connected to the AC power.
Disconnect all necessary cable connections.
Failure to observe these
warnings could result in personal injury or
damage to the equipment.
注意!
确保系统未开机且未连接到交流电源。
断开所有必要的线缆连接。若不遵循这些
警告,可能造成人员伤害或设备损坏。
1
2
CAUTION!
Read the following guidelines before you begin to install the Hard disk drive:
Take note of the drive tray orientation before sliding it out.
The tray will not fit back into the bay if inserted incorrectly.
Make sure that the HDD is connected to the HDD connector on the backplane.
注意!
在滑出驱动器托盘之前,注意其方向。
托盘插入不当时,无法进入托槽。
确保硬盘驱动器连接到底板上的硬盘驱动
器底板。
No
Description
1
HDD#3
2
HDD#2
3
HDD#1
4
HDD#0
5
SGPIO header
6
Fan connector#13
7
Fan connector#14
8
Fan connector#11
9
Fan connector#12
10
ODD power connector
11
Fan connector#9
HDD Backplane Board Components
No
Description
12
Fan connector#10
13
Fan connector#7
14
Fan connector#8
15
Fan connector#5
16
Fan connector#6
17
Fan connector#3
18
Fan connector#4
19
Fan connector#1
20
Fan connector#2
21
Fan connector#15
22
Fan connector#16
Hard Disk Drive and Back Plane Board/
硬盘驱动器与硬盘驱动器底板
5
1
2
3
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
3
4
4
1
2
System Front View
System Rear View
No
Description
1
ID button w/LED
2
Power button w/LED
3
HDD bays
No
Description
1
Power supply fan
2
Power supply module cord socket
3
System Status LED
4
Power button w/LED
5
ID switch button w/LED
6
VGA port
7
USB 3.0 ports
8
10/100/1000 Server management LAN port
9
GbE LAN ports
10
SFP+ LAN ports
Front & Rear/
系统前部与后部概览
Off
State
Description
Yellow On
1Gbps data rate
Green On
100Mbps data rate
10Mbps data rate
State
Description
Yellow On
1Gbps data rate
Green On
10 Gbps data rate
Speed LED Link/Activity
LED
Speed LED Link/Activity
LED
SFP+ LAN LED:
ID button/LED:
Power button/LED:
Blue On
System identifcation is active.
Off
System identifcation is disabled.
State
Description
Green On
Off
Description
System is powered on
System is powered off
State
1
2
3
1
2
3
4
5 6
7 8 9
10
PCI Express Card/PCI Express
扩展卡
注意!
在安装扩展卡前,请注意下列事项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the PCI express card:
Make sure the system is not turned on or connected to AC power.
1
2
3
4
5
6
7
8
注意!
在替换或安装电源前,请注意下列事项:
确保系统未开启且未连接到交流电源
。
CAUTION!
Before you remove or install the power
supplies:
Make sure the system is not turned on or
connected to AC power.
Power Supply/
电源
1
2
3
Rail Kit/
导轨
Release
Lock out
⯮ⅎ庳⎽⇡
Release and detach the inner member from the slide
1
M4X6
Click
Aach the unit to the inner member
⯭Ⅼ彏擨ᷱ㜡⏗
2
Release
lock in
Insert the unit to complete the installaon
墬⅌㜡㞝
4
Bracket
M6X13
M6-NUT
Fix the outer member/bracket assembly to the frame
⯭⣽彏㈿㞝擨⅌㜡㞝
3
Front Panel LED and Buttons/
前面板 LED 说明
7
复位按钮
按此按钮启动系统。
8
复位按钮
按此按钮启动不可遮罩中断功能。
2
按下按钮启动系统识别功能。
ID按钮
1
系统处于开机状态。
系统处于ACPI S1状态(睡眠模式)。
系统未开机或处于ACPIS5状态(关机状态)。
系统处于ACPI S4状态(休眠模式)。
电源按钮和LED
绿色
绿色
恒亮
不亮
闪烁
无亮灯
不亮
断开连接/待机
无亮灯
5/6
恒亮
闪烁
系统和网络之间的链接
网络访问
绿色
绿色
LAN1/LAN2活动LED
6
硬盘驱动器定位
硬盘驱动器访问
硬盘驱动器访问
硬盘故障
无硬盘驱动器访问
绿色
橙色
绿色/橙色
不亮
亮
亮
闪烁
无亮灯
硬盘驱动器LED
闪烁
编号
名称
颜色
状态
说明
3
系统正常运行
。
橙色
绿色
系统状态LED
恒亮
恒亮
不亮
不亮
闪烁
无亮灯
效能降低情形,可能为下列状况:
处理器问题
内存问题
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
No.
Name
Color
Status
Description
7
Reset Button
Press the button to reset the system.
8
NMI Button
Press the button to generate an NMI.
2
Press the button to activate system identifcation.
ID Button
1
System is powered on.
System is in ACPI S1 state (sleep mode).
System is not powered on or in ACPI S5 state (power off).
System is in ACPI S4 state (hibernate mode).
Power Button and LED
Green
Green
Solid On
Off
Blink
N/A
4
HDD locate
HDD access
HDD access
HDD fault
No HDD access or no HDD fault.
Green
Amber
Green/Amber
On
Off
Blink
On
Blink
N/A
HDD Status LED
5/6
Link between system and network or no access.
Data transmission or receiving is occurring.
No data transmission or receiving is occurring.
Solid On
Off
Blink
Green
Green
N/A
LAN1/2 Active/Link LEDs
状态
3
System is operating normally.
Degrade condition, may indicates:
CPU failure
DIMM killed
System Status LED
Green
Amber
Solid On
Critical condition, may indicates:
Power module failure
System fan failure
Power supply voltage issue
System temperature
Solid On
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicates:
POST error
NMI error
Processor or terminator missing
Blink
N/A
N/A
Off
1
2
3
4
5
6
7
8
G150-B10 Quick Installation Guide/G150-B10
快速安装说明
10/100/1000 LAN LED:
1
2
3
4 5
6
7
9
8
10
PN:25ME0-G15000-CLS