background image

8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan

Phone: (886) 2-2695-4214 

FAX: (886) 2-2695-4213 

1

Summary of Contents for MFR200

Page 1: ...8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Hsien 221 Taiwan Phone 886 2 2695 4214 FAX 886 2 2695 4213 1 ...

Page 2: ...on applications Designed for card data collection anytime and anywhere without computer connectivity The data is read from reader and shown on the display and kept into the memory with time stamp and downloaded to the computer The data is read from card reader and shown on the display and kept into the memory with time stamp and downloaded to the computer Physical reader can read 13 56MHz cards MF...

Page 3: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inte...

Page 4: ...the electrical device if the device is not going to be used for a long time 5 Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to...

Page 5: ...ectrical device if the device is not going to be used for a long time 5 Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to recha...

Page 6: ...Information 6 ...

Page 7: ...efective card misread bad memory or incorrectly encoded data and so on the device will turn on the ERROR indicator Scan the RFID card to reader Put the battery in box and hold battery For connection to host computer and external Power Turn the PCR200 MFR200 on off power and Operate Operation LED Indicator LCD Main Screen Chain Sling Hole Connect to chain sling 7 ...

Page 8: ...cel No Key Function Up Up scroll Decrease Scan Key Function Down Down scroll Increase Event Key Function Menu Enter Save Next Yes Key Function Technical And Operational Description Display Date Week Time Menu Item Record Data Parameter Setting Other Information EM Buzzer ON Event Mifare DESFire Card Decoded Mifare 1K Card Decoded 1K Mifare Ultralight Card Decoded UT Mifare 4K Card Decoded 4K Felic...

Page 9: ...OFF Default ON Reset Default BackLight 15 seconds Auto Power Off 30 seconds Power Mode Switch Mode Sound ON Display Memory Status Used T Unused T Used R Unused R Display all records in memory Set Date Format Select Year Month Date Date Month Year Month Date Year Default Month Date Year Set Date Year Month Date Set Time Week Hour Minute Second Technical And Operational Description Select Mode ID Nu...

Page 10: ...er scan card No Record in FLASH memory Enter Database View function The FLASH memory not empty Enter Calendar function Enter FMM Mode By communication command The record already is full After scan card Set Date and Time Contact Agent Scah Card again or Change Card Swipe Card Download Records and Erase Records Update New Firmware Download Records and Erase Records 10 ...

Page 11: ...he RTC is malfunctioning and you must do the RTC time setting before you use the unit When the device is powered by battery it would have Low Battery Detect function When the battery goes low the LCD would display and you must change battery immediately otherwise the unit would shut down any time without pre warning Log database memory is full You are not able to add any new records Free the log d...

Page 12: ...nical and Operational Description 1 Read the instructions on your device before replace new battery 2 PCR200 MFR200 can used Single cell alkaline nickel cadmium NiCd or nickel metal hydride NiMH Battery 12 ...

Page 13: ...h an external power adapter it would be turned On Off automatically 2 When PCR200 MFR200 is not connected with an external power adaptor the corresponding key for power on PCR200 MFR200 needs to be pressed all the time during the communications with the PC 13 ...

Page 14: ...Connections 1 When PCR200 MFR200 is connected disconnected with USB port it would be turned On Off automatically 14 ...

Page 15: ...15 ...

Page 16: ...table or Any surface Version 1 2 GNET V1 2 CMOS Serial Flash Memory 2048K bytes Up to 65536 records 16 Bytes Record Real Time Clock RTC module and back up capacitor Full compliance with the USB Specification V 1 1 The device uses a Virtual Serial Port Driver making it appear to have the software like a standard RS232 Serial Port LR03 AAA LCD type FSTN Dot arrangement 101 x 67 Dots Matrix LCD Modul...

Page 17: ...ACK NACK TIME OUT NACK 2 B Start of Text 02 13 M Carriage Return 0d ASCII ASCII Command Code ASCII ASCII ASCII Contents Data ASCII ASCII ASCII Check Sum ASCII 78 65 N A Negative Acknowledge 4e 41 17 ...

Page 18: ...t Password Logout Erase All Record Get Machine ID Set Machine ID Access Denied Invalid Command or Data Command Execution Failed Database is Empty PCR200 MFR200 Terminal has an extensive list of Commands that allow manipulating its internal database setting functional parameters and getting data on its current status There are 2 levels of access to the PCR200 MFR200 User and Supervisor Supervisor l...

Page 19: ...Communication Protocol 19 ...

Page 20: ...Communication Protocol 20 ...

Page 21: ...Communication Protocol 21 ...

Page 22: ...Communication Protocol ROM Txxxx xxxx Rom serial number Vx xxRm Vx xx Firmware version x xx Rm Modify m times Year 2000 20xx Month 01 12 Date 01 31 Hour 00 23 Minute 00 59 Second 00 59 22 ...

Page 23: ...Communication Protocol Year 2000 20xx Month 01 12 Date 01 31 Hour 00 23 Minute 00 59 Second 00 59 Week 0 6 23 ...

Page 24: ...Communication Protocol 24 ...

Page 25: ...h 20 2Fh 00 FFh 0 255 second 00h Auto Power Off FFh Switch 00 FFh 00 FFh 0 255 second 00h Off FFh On 00h mm dd yyyy FFh yyyy mm dd other dd mm yyyy ID Number 0 1h only 0 event 2h 0 1 event nh 0 n 1 event Max n 10 10 FFh 0 9 event 16 Characters 30 1FBh Scan Mode 1Fh 00h continuous Mode other Button Mode 1Ch RFID scan time 1Dh 05 FEh 5 254 second FFh 10 second Time Lock Mode 50h 00h Lock FFh Nolock ...

Page 26: ... 00h White List Total 0 Record Total 65536 01h White List Total 256 Record Total 65024 02h White List Total 512 Record Total 64512 03h White List Total 768 Record Total 40h White List Total 16384 Record Total 32768 80h White List Total 32768 Record Total 0 Communication Protocol Password 1FC 1FFh 4 Characters 26 ...

Page 27: ...Record Total 65536 White List Total 32768 White List Total 16384 Record Total 32768 Communication Protocol 27 ...

Page 28: ...Communication Protocol 28 ...

Page 29: ...Communication Protocol 29 ...

Reviews: