background image

Appendix

Disposal

24 of 27

User Manual Cash Control Unit 1.0/Edition 12.2009

ID No. 30033908

B

Disposal

Environmental 
Protection

Fig. 16

WEEE symbol

In accordance with the European Directive 2002/96/EC on waste electri-
cal and electronic equipment (WEEE), the following applies:
– Electrical and electronic devices may not be disposed of with domes-

tic waste.

– Consumers are obliged by law to return electrical and electronic de-

vices at the end of their service lives to the public collecting points set 
up for this purpose or point of sale. Details to this are defined by the 
national law of the respective country. 

– The symbol on the product or package indicates that this product is 

subject to these regulations. 

By recycling, reusing the materials or other forms of utilizing old devices, 
you are making an important contribution to protecting our environ-
ment.

Summary of Contents for Cash Control Unit 1.0

Page 1: ...Cash Control Unit 1 0 Certified Transaction Logging for Cash Registers in Sweden User Manual Edition 12 2009...

Page 2: ...trademarks or trademarks of Kingston Technology Company Inc Lexar is a trademark of Lexar Media Inc Panasonic is a registered trademark of Panasonic Corporation PNY is a registered trademark of PNY T...

Page 3: ...4 1 Understanding Cash Control Unit 5 1 1 Connections and SD Slot 6 1 2 LEDs 8 1 3 DIP Switches 9 1 4 Security Seal 11 1 5 Product Label 13 2 Working with Cash Control Unit 15 2 1 Connecting and Disco...

Page 4: ...Contents User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Page 5: ...see 1 4 Security Seal on page 11 and see 1 5 Product Label on page 13 Features Cash Control Unit comprises the following features Type A configuration 2 GB internal flash memory for at least seven mil...

Page 6: ...7 7B1 IEC 721 3 7 7C1L IEC 721 3 7 7M1 IEC 721 3 7 7M2 drop Brand Size and Format Digi Photo Premium 1GB SD 2GB SD FujiFilm 1GB SD 4GB SDHC GreenMemory 4GB SDHC 8GB SDHC Kingston 2GB SD 4GB SDHC Lexar...

Page 7: ...2009 3 of 27 ID No 30033908 CE EN 55022 Category B EN 55024 EN 60950 1 RoHS WEEE Protection class IP41 Delivery Extent The Cash Control Unit package comprises Cash Control Unit Power supply RS232 cabl...

Page 8: ...rized tax authority of ficers and cashiers Notational Conventions The following symbols are used in this manual Tips give advice about the best way to do something or useful informa tion on special as...

Page 9: ...ontrol Unit User Manual Cash Control Unit 1 0 Edition 12 2009 5 of 27 ID No 30033908 1 Understanding Cash Control Unit This chapter describes the basic principles of Cash Control Unit and pro vides ba...

Page 10: ...as power supply only The serial port is used to communicate with the ECR via the RS232 cable provided Communication speed can be set using the DIP switches see 1 3 DIP Switches on page 9 Serial Port P...

Page 11: ...Unit provides an SD slot for transferring data to a storage card Fig 4 SD slot The SD slot is always covered by a seal to prevent tampering For more information on seal placement and how to insert the...

Page 12: ...ate ON Green DATA Yellow ERROR Red Normal operation on off off Data transfer to SD on blinking off Data transfer to SD completed on on off SD card removed after transfer com pleted ie normal operation...

Page 13: ...hes 1 and 2 are used in this configuration of Cash Control Unit In the following table UP means towards the top of Cash Control Unit and DOWN means towards the bottom of Cash Control Unit as indicated...

Page 14: ...009 ID No 30033908 Seal The DIP switches should be sealed after being set to prevent accidentally changing the configuration and to prevent any dust or liquids from en tering the housing The figure be...

Page 15: ...seal is destroyed when it is removed When the seal is peeled back it leaves visible marks on Cash Control Unit Any tampering attempts aimed at illicitly detaching a seal for example by means of solven...

Page 16: ...27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908 Fig 9 Security seals over SD slot and on the front of Cash Control Unit Fig 10 Security seal on the back of Cash Control Unit Fig 1...

Page 17: ...ope Cash Control Unit is certified in accordance with Swedish Tax Agency regulation SKVFS 2009 2 The serial and certificate numbers and the certification seal are found on the product label attached t...

Page 18: ...Understanding Cash Control Unit Product Label 14 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Page 19: ...Control Unit 1 0 Edition 12 2009 15 of 27 ID No 30033908 2 Working with Cash Control Unit This chapter describes how to connect and disconnect Cash Control Unit and how to transfer control data from C...

Page 20: ...ly experienced per son Fig 13 Cash Control Unit connections Connecting Cash Control Unit To connect Cash Control Unit to the electronic cash register 1 Set the DIP switches to the communication speed...

Page 21: ...g This can take about 30 sec onds Cash Control Unit is ready for use Disconnecting Cash Control Unit Do not disconnect Cash Control Unit from power supply if not necessary Make sure no data transfer i...

Page 22: ...bel on page 13 How to Proceed No receipts can be processed while data is being transferred from Cash Control Unit Fig 15 Inserting storage card To transfer data from Cash Control Unit to a storage car...

Page 23: ...Data User Manual Cash Control Unit 1 0 Edition 12 2009 19 of 27 ID No 30033908 6 When data transfer has been completed and the yellow DATA LED has stopped blinking remove the storage card from the SD...

Page 24: ...Working with Cash Control Unit Transferring Data 20 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Page 25: ...Appendix User Manual Cash Control Unit 1 0 Edition 12 2009 21 of 27 ID No 30033908 Appendix The appendix contains additional information on Cash Control Unit and the index...

Page 26: ...rol Unit must be used as specified in the product documen tation Electrical installation of Cash Control Unit must meet Swedish re quirements and regulations Only use the power cable that comes with C...

Page 27: ...wer cable wires must be selected according to the maximum electrical specifications on the product label as stipulated by EN60950 1 VDE0100 EN60204 or UL508 regulations The devices do not generally fu...

Page 28: ...d of with domes tic waste Consumers are obliged by law to return electrical and electronic de vices at the end of their service lives to the public collecting points set up for this purpose or point o...

Page 29: ...Set Ready DTR Data Terminal Ready ECR electronic cash register FAT File Allocation Table GND Ground LED Light Emitting Diode LVD Low Voltage Directive RS232 Recommended Standard 232 a standard for ser...

Page 30: ...Appendix Glossary 26 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Page 31: ...procedure 16 connections 6 conventions 4 D delivery extent 3 DIP switches 9 seal 10 disconnect procedure 17 disposal 24 F features 1 L LEDs 8 N notational conventions 4 P power supply 6 product label...

Reviews: