Giebel Adsorber MA-R Assembly And Maintenance Instructions Download Page 1

 

Assembly and maintenance 

instructions

 

according to regulation DIN 82079

 

Version 06.20 

Date: 21.10.2021 

Name: Manual_MA-R_EN

 

 

GIEBEL FilTec GmbH 

[email protected] 

| Accessories & Spare parts

shop.giebel-adsorber.de

 

1/8 

 Adsorber MA-R 

Section 1: 

Information on the manufacturer 

 

Giebel FilTec GmbH 

Carl-Zeiss-Str. 5 
74626 Bretzfeld 
Germany 

Tel. +49 79 46 94 44 01 0 
Fax +49 79 46 94 44 01 29 
E-Mail 

[email protected]

  

 

 

Section 2: 

Product overview 

 

 

Sizes 

Size 2 

Size 3 

Size 5 

MA-R 2L 

MA-R 3M / MA-R 3L 

VV-R 5M 

 

 

 

Materials used 

Aluminium, acrylic glass, stainless steel, polyoxymethylene (POM), FKM, EPDM, silica gel orange, 
activated carbon 

 

REACH Note 

No ingredients requiring disclosure under Regulation (EC) No 1907/2006. 

 

 

Summary of Contents for Adsorber MA-R

Page 1: ...ion on the manufacturer Giebel FilTec GmbH Carl Zeiss Str 5 74626 Bretzfeld Germany Tel 49 79 46 94 44 01 0 Fax 49 79 46 94 44 01 29 E Mail info giebel adsorber de Section 2 Product overview Sizes Siz...

Page 2: ...culate filter Filter element with 3 m separation efficiency Seal material FKM EPDM Operating temperature 40 C 80 C Connection BSP NPT Metric Slipfit Section 4 Technical data VV R 2L VV R 3M VV R 3L VV...

Page 3: ...iebel adsorber de 3 8 Section 5 Assembly and commissioning 1 Remove protective foil on the underside of the adsorber 2 Lightly oil the thread 3 Screw the adsorber onto the system Section 6 Maintenance...

Page 4: ...isk 8 Insert a new filter element and then fill in fresh desiccant When filling in the desiccant lightly tap the housing with a soft object e g the ball of your hand to compact the bulk material 9 Ins...

Page 5: ...ry rooms at 10 C to 30 C Section 8 Disposal Regeneration In practice the most common regeneration method used is the temperature increase When desorbing water vapour from silica gel the temperature mu...

Page 6: ...any oil particles enter the adsorber the oil particles close the pores of the desiccant and thus prevent adsorption Ambient temperature too high If the ambient temperature exceeds 80 C the binding for...

Page 7: ...essure range of the system The adsorber should not be exposed to over or underpressure above 0 5 bar otherwise the housing may be damaged Thread of the adsorber and accessories is damaged When mountin...

Page 8: ...resh silica gel should be used 3 Check filter unit for impurities Check Take off the lid and remove the activated carbon disc Then empty the desiccant The filter unit can then be removed This should b...

Reviews: