70
4.4 ENERGYPAK-BATTERY
ENERGYPAK FITTING IMPROVEMENT S.O.P.
MY19 FITTING INTEGRATED TOP RELEASE ENERGYPAK
PART 2: CHECKING AND ADJUSTING LOCK ALIGNMENT
1
Before proceeding, make sure part 1 of the S.O.P. is finished (Replace-
ment of cover rubbers).
Open the lock and remove the EnergyPak from the bike. Place the Ener-
gyPak on a non-scratching surface.
2
Loosen and take out the upper bolt of the lock assembly.
3
Place the battery positioning tool in to the frame and make sure it’s se-
cured by the lock.
4
Fix the battery positioning tool onto the lock assembly by tightening the
bolt, this bolt will come with the battery positioning tool.
5
Locate the 3 bolts that fix the lock in place and loosen them. Do not take
them out.