13
closing is disabled when you set 0 second. No jumper connected means 0 second.
When jumper 1 connect with jumper 2 it means 10 seconds. When jumper 2 connects
with jumper 3 it means 5 seconds. The LED indicator for auto closing time count
down flashes every 1second.
11. Motor delay time protection: As soon as the motor running continuously
more than 60s, the motor will automaticlly stop working to protect the motor.
12. Motor direction indentification:When one side of door installed thrust plate
or the contoller has function of setting order of opening & closing, or functions of
swiping card, make sure all the wiring connections of 2 motors are correct. When the
motor is running, if motor direction LED indicator is blue, now the motor should be in
“opening”operation, if no, please exchange the wiring connections of 2 motors; when
the motor direction LED indicator is RED, the motor should be in the
“closing”operation. If no, please exchage the wiring connections. Otherwise can not
open and close the door normally.