Description:
For the wider door leaf, we suggest that you can extend the opening and closing time or adjust to the
higher torque output.
The high torque output enhanced the door brakemotion stability.
The opening operation based on 90° angle; however, there would be time difference from the setting angles.
The TC settings of maintain-open time and obstacle time should be the same.
If the obstacle setting is too long, please push the door manually to reset.
If the door doesn’t close, please remove the obstacles.
In strong wind place, please set locked status on DIP3 and adjust to high torque output.
Safety Device:
Do not push/pull the door with excessive force during proper operation. Excessive force will lead to
auto shut off by control board and recovery after 10 seconds.
Automatic Door Operator
Manual
6
fastest
13 sec.
1 sec.
fast
15 sec.
5 sec.
slow
20 sec.
10 sec.
slowest
23 sec.
20 sec.
Obstacle Setting
Door Leaf
Torque Output
Brake
Door Leaf
70kg Low
70kg
(light)
70kg High
70kg
(heavy)
Opening and
Closing Speed
Opening and
Closing
Operation
Total Opening
and Closing
Time
Maintain-open
Time Adjustment
Maintain-open
Time
(See P. 8
Figure 4)
TC
VM
Parameter illustration table
*VM setting: Dimension: W80cm x H213cm/ Weight: 65kg
*Total Time: opening & closing opbrake time+main+open time (1 sec.)