Giacomini GE552 Series Manual Download Page 1

1

0388EN  July 2015

M

etering

 

systeMs

V

olumetric

 

thermal

 

energy

 

meters

ge552 

series

ISO

14001

0032A/3

OHSAS

18001

0064L/1

ISO

9001

0006/7

Electronic part

Temperature range [°C]

0÷105

Temperature difference range [K]

3÷80

Display

LCD with 8 f special symbols

Ambient temperature range [°C]

5÷55

Minimum temperature difference [K]

3

Measuring frequency [s]

30 seconds

Heat quantity representation

MWh

Data backup

Once a day

Interface

M-Bus

Power supply

3,6 V lithium battery

Battery lifespan 

> 6 years

Protection class

IP54

EMV

C

Mechanical/electromagnetic class

M1 / E1

Accuracy class

3

Volumetric part

Product code

GE552Y158 GE552Y159 GE552Y160

Nominal Qp flow rate [m³/h]

0,6

1,5

2,5

Maximum Qs flow rate [m³/h]

1,2

3,0

5,0

Minimum Qi horizontal flow rate [l/h]

12

30

50

Minimum Qi vertical flow rate [l/h]

12

30

50

Start-up horizontal flow rate [l/h]

4

4

5

Temperature range [°C]

10÷90

Nominal pressure PN

16

Pressure loss at Qp [bar]

< 0,25

Nominal diameter DN

15

15

20

Length [mm]

110

110

130

Installation position

horizontal or vertical; NOT upside down

Cable length [m]

1,2

Installation point for the

temperature probe

M10 x 1

Fluid

water

Losses of pressure

0,001

0,01

0,1

1

10

0,1

1

10

Q [m

3

/h]

Δ

p [bar]

3/4”

1”

Product code

Connections

Kv

GE552Y158

3/4"

3,0

GE552Y159

3/4"

3,0

GE552Y160

1”

5,6

Description

The GE552 volumetric single jet energy meter is characterised by its consistent 
accuracy over time and its remarkable operating safety; high precision 
measuring capability means that this device can be used across a wide range 
of applications. The meter is available in 3/4” versions (nominal flow rate of 
0,6 or 1,5 m³/h) and 1” versions (nominal flow rate of 2,5 m³/h). It is equipped 
with a double register, and can therefore measure the thermal energy of both 
heating and cooling operations. The temperature range of the meter makes 
it ideal for metering energy consumption in residential buildings equipped 
with a centralised heating/conditioning system and zone distribution.

Versions and product codes

Product code Connections

Centre 

to centre 

assembly 

distance 

[mm]

Nominal

flow rate 

[m

3

/h]

Flow rate

min.

[l/h]

Flow rate

max.

[m

3

/h]

GE552Y158

3/4"

110

0,6

12

1,2

GE552Y159

3/4"

110

1,5

30

3,0

GE552Y160

1”

130

2,5

50

5,0

Main characteristics

Its particularly compact structure makes it suitable for any type of installation. 
The electronic part can be separated to allow installation in even the smallest 
metering cabinets. Easy to use, by means of one single key. The display is 
easy to read, and shows all the most important operating conditions. Its 
reliability and notable measuring performance ensure excellent measuring 
results throughout its working life. Thanks to the use of the most advanced 
electronics (free of electromagnetic interference), it satisfies all the current 
requisites in terms of measuring techniques for compact meters.

Technical data

Temperature probes

Resistance to platinum

Pt1000

Diameter and type of probe

5 mm (DS according to EN 1434)

Temperature range [°C]

0÷105

Cable length [m]

1,5

Installation points

delivery

direct immersion or in immersion 

housings (existing systems)

return

probe integrated in the volumetric part

GE552