GIA GIATSU WAVE GIA-VEI-09V1 Owners And Installation Manual Download Page 1

OWNER’S AND INSTALLATION

MANUAL

MOBILE HOME AIR CONDITIONER

ENGLSI

H

WAVE

Thanks for choossing our product. 

Please, read carefully this manual 

before using the product 

GIA-VEI-09V1

 | 

GIA-VEI-12V1

Summary of Contents for GIATSU WAVE GIA-VEI-09V1

Page 1: ...OWNER S AND INSTALLATION MANUAL MOBILE HOME AIR CONDITIONER ENGLSIH WAVE Thanks for choossing our product Please read carefully this manual before using the product GIA VEI 09V1 GIA VEI 12V1...

Page 2: ...ended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning u...

Page 3: ...be far away from obstacles and do not put any objects near air outlet Otherwise it will affect the radiation of heat removal pipe not affect neighborood 4 The appliance shall not be installed in the l...

Page 4: ...from a 220 240V AC 50Hz 1 Phase power supply 4 The wiring diagrams are located on the cover of the control box The assembly unit wire diagrams are located on the ceiling panel 1 Thank you for choosing...

Page 5: ...OARD YEGN GN BU WH BN L N POWER PE L N BU YEGN BN BK TERMINAL BLOCK CAP WH BU BU R S INDOOR UNIT OUTROOM SENSOR Y A W 4 N VALVE 4 WAY 4YV MOTOR DISP1 N1 COMP PE OUT_FAN AC L1 PE BU BN YEGN DISP2 AP1 Y...

Page 6: ...WH BN L N POWER PE L N BU YEGN BN BK TERMINAL BLOCK CONNECTOR AP3 WIFI MODULE WIFI CAP WH BU S BU R INDOOR UNIT OUTROOM SENSOR N 4WAY VALVE 4 WAY 4YV MOTOR DISP1 N1 COMP PE OUT_FAN AC L1 PE BU BN YEGN...

Page 7: ...f a i r ve n t D o u b l e si d e d g u m m e d p a p e r M 8 X 1 3 5 4 Ta p p i n g scr e w S T4 2 X 9 5 TA 8 S cr e w ca p 6 S u n k scr e w 2 r e m o t e co n t r o l l e r h o l d e r b a t t e r...

Page 8: ...n e D i s p l a y c o n t e n t o r p o s i t i o n m a y b e d i f f e r e n t f r o m a b o v e g r a p h i c s p l e a s e r e f e r t o a c t u a l p r o d u c t s I n d o o r U n i t O u t d o o...

Page 9: ...b u t t o n 1 3 S L E E P b u t t o n 1 4 L I G H T b u t t o n C L O C K b u t t o n b u t t o n 1 3 5 7 9 1 2 2 4 6 8 1 1 1 0 1 4 1 3 Tu r b o m o d e S e n d s i g n a l S e t t e m p e r a t u r e...

Page 10: ...e f a u l t w h i l e p o w e r o n U n d e r A u t o m o d e t h e t e m p e r a t u r e w i l l n o t b e d i s p l a y e d U n d e r H e a t m o d e t h e i n i t i a l v a l u e i s 2 8 8 2 U n d...

Page 11: ...p e r a t i v e b u t t o n 7 P r e s s t h i s b u t t o n t h e c l o c k c a n b e s e t u p s i g n a l b l i n k a n d d i s p l a y W i t h i n 5 s e c o n d s t h e v a l u e c a n b e a d j u...

Page 12: ...up the temperature displaying status that will display the setting temperature This function is applicable to partial of models After powered on the setting temperature displaying is defaulted accordi...

Page 13: ...o r f a n w i l l s t o p r u n n i n g Th e u p p e r a n d l o w e r g u i d e b o a r d r o t a t e t o h o r i z o n t a l p o s i t i o n t h e n t h e i n d o o r f a n w i l l r u n a t l o w f...

Page 14: ...t e w h e n i t i s p o w e r e d o n t h e g u i d e 2 P r e s s M O D E b u t t o n s e l e c t d e s i r e d r u n n i n g m o d e 3 P r e s s i n g o r b u t t o n t o s e t t h e d e s i r e d t...

Page 15: ...ttery Cover of battery box remove reinstall ntrol signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there shoul...

Page 16: ...e install the air filter power on and turn on the unit the light will still be on press FILTER CHECK button the light will turn off 4 TIMER button Press the button to increase the set operating temper...

Page 17: ...r off the unit take the air filter out and clean it then re install the air filter power on and turn on the unit the light will still be on press FILTER CHECK button the light will turn off 4 WIFI but...

Page 18: ...res Once the location for your air conditioner has been determined A reinforced and framed roof hole opening must be cut if there is no hole or you may use existing vent holes CASE A If a roof vent is...

Page 19: ...ing occurs A typical support frame is shown in Figure 1 CAUTION 1 The roof top air conditioner must be mounted on a level plane from front to rear and side to side when the vehicle is parked on a leve...

Page 20: ...Level 0 Max Figure 2 Note Try you best to put the unit on the horizontal surface for operation The unit can only operate for a short time at the maximum sloping angle of 5 for preventing water leakag...

Page 21: ...ille at the back of outer case see Figure4 1 2 Fix the outdoor unit at the roof of vehicle and then drill holes 1 Place the outdoor unit at the roof of vehicle lift the outdoor unit and then place the...

Page 22: ...assembly frame to the gasket has been evenly compressed roof top air conditioner with the mounting bolts see Figure 5 You must start thread themounting bolts by hand to avoid cross threading DO NOT S...

Page 23: ...he power cord and make it get into the box through the strain relief that is provided see Figure 7 4 Connect the power cord to the brown blue and ground wires found in the junction box with a terminal...

Page 24: ...y and check the unit work or not 5 Install screw caps into four screw holes 4 Check the thermostat position Make sure the thermostat is routed through the holding guide and is not touching any metal s...

Page 25: ...ear and side to side when the vehicle is parked Make sure that the mounting of the air conditioner is correct and level Reset the remote control to a lower temperature setting Remove and clean the fil...

Page 26: ...an electric household vacuum cleaner HOW TO DISMANTLE CLASP 1 Concrete dismantle method use the similar tool in Figure b align the clasp core and insert it as Figure a is shown The inserted depth is a...

Page 27: ...map of clasp in different status Choose appropriate size that fits your hand feeling Length of handle choose appropriate length that fits your hand feeling Clasp core Before Figure a Figure b Figure...

Page 28: ...ain the refrigeration system which has the high internal pressure 3 Do not block the filter and the indoor air inlet badly to prevent water leakage 1 Don t touch the capacitor terminals without the el...