Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket

with even strength, and pull it

out from the unit.

3. Pour the water out.

There are two ways to remove collected water.

1. Use the bucket

When the unit is off,if the bucket is full, the unit will 

beep 8 times and the Full Water indicator light will flash.

When the unit is on,if the bucket is full, the compressor 

turns off and the fan turns off after 30 seconds for drying

the water of the condenser, then the unit  will beep 8 

times and the Full Water indicator light will flash.

Slowly pull out the bucket. Grip the left and right 

handles securely, and carefully pull out straight so 

water does not spill. Do not put the tank on the floor 

because the bottom of the bucket is uneven. Otherwise 

the bucket will fall and cause the water to spill.

Throw away the water and replace the bucket. The 

bucket must  be in place and securely seated  for the 

dehumidifier to operate.

The machine will re-start when the bucket is restored

in its correct position.

NOTES:

    When you remove the bucket, do not touch any parts 

     inside of the unit. Doing so may damage the product.

     Be sure to push the bucket gently all the way into the 

     unit. Banging the bucket against anything or failing to 

     push it in securely may cause the unit not to operate.

     When you remove the bucket,if there is some water in

     the unit you must dry it .

Fig.5

Fig.6

OPERATING THE UNIT

3. Clean the air filter

Fig. 8

After turning off the unit, wait one day before emptying 

the bucket.

Clean the main unit, water bucket and air filter.

Cover the unit with a plastic bag.

Store the unit upright in a dry, well-ventilated place.

4. When not using the unit for long time periods

CARE AND MAINTENANCE

Care and cleaning of the dehumidifier

Turn the dehumidifier off and remove the plug 

from the wall outlet before cleaning.

1. Clean the Grille and Case

Use water and a mild detergent. Do not use bleach 

or abrasives.

Do not splash water directly onto the main unit. Doing

so may cause an electrical shock, cause the insulation

to deteriorate, or cause the unit to rust.

The air intake and outlet grilles get soiled easily, so use

a vacuum attachment or brush to clean.

2. Clean the bucket

Every few weeks, clean the bucket to prevent growth of mold,

mildew and bacteria. Partially fill the bucket with clean water 

and add a little mild detergent. Swish it around in the bucket,

empty and rinse.

NOTE:

 Do not use a dishwasher to clean the bucket.

After clean, the bucket must be in place and securely 

seated for the dehumidifier to operate.

2. Continuous draining

Fig.7

NOTE: When the continuous drain feature 

is not being used,remove the drain hose 

from the outlet.

Attach the hose 

to the drain 

hose outlet.

Remove the 

rubber plug

Water can be automatically emptied into a floor 

drain by attaching the unit with a water hose

(not included).

Remove the rubber plug from the back drain

hose outlet. Attach a drain hose(ID=15mm)

and lead it to the floor drain or a suitable

drainage facility(see Fig.7).

 

Make sure the hose is secure so there are no leaks.

Direct the hose toward the drain,making sure that

there are no kinks that will stop the warter flowing.

Place the end of the hose into the drain and make sure

the end of the hose is level or down to let the water flow

smoothly.Do never let it up.

Select the desired humidity setting and fan speed 

on the unit for continuous draining to start.

Fig. 9

Fig. 10

The air filter behind the front grille should be

checked and cleaned at least every 30 days

or more often if necessary.

NOTE: DO NOT RINSE OR PUT THE FILTER

IN AN AUTOMATIC DISHWASHER.

To remove:

Grip the tab on the filter and pull it outward, then 

pull it up as shown in Fig.8.

Clean the filter with warm, soapy water. Rinse and

let the filter dry before replacing it. Do not clean the

filter in a dishwasher.

To attach:

Insert the air filter into the unit from underside to 

upside. See Fig.10.

CAUTION:

DO NOT operate the dehumidifier without a filter

because dirt and lint will clog it and reduce

performance.

Summary of Contents for GIADB30X8DSG

Page 1: ...OWNER S MANUAL DEHUMIDIFIER ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product X8DSG GIADB30X8DSG...

Page 2: ...ast free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Page 3: ...of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance...

Page 4: ...d Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTION...

Page 5: ...nit If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water container on top of the unit The manufactures na...

Page 6: ...rol to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Low POWER MODE SWING FAN TIMER 3S NOW SET AUTO SHOES CLOTHES 1 2 3 4...

Page 7: ...THES mode indicator light AUTO mode indicator light AUTO mode The unit can be set desired humidity level fan speed and louver swing feature SHOES mode The unit can make the MAX dehumidification functi...

Page 8: ...tion of parts Fig 2 Fig 3 Water bucket Control panel Handle both sides 1 2 3 4 1 2 3 4 NOTE All the pictures in the manual are for explanation purposes only Theactual shape of the unit you purchased m...

Page 9: ...spill water Adehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of t...

Page 10: ...on NOTES When you remove the bucket do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way into the unit Banging the bucket against any...

Page 11: ...an the bucket Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket em...

Page 12: ...er The humidity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or somet...

Page 13: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Reviews: