background image

Quick guide to the installation of the  
HDMCS series compatc weather stations 

The guide outlines the installation of the 

HDMCS100

 and 

HDMCS200 

weather stations. The station 

starts storing and sending data to “

www.deltaohm.cloud

” Cloud as soon as it is powered. 

For a detailed description of the operation of the sensors and data logger, carefully read the 

corresponding user manuals and the instructions of the HD35AP-S software. 

 

 

Unpacking 

Remove the packaging of the various parts of the 

system (acquisition system, sensors, supports, 
accessories). Handle all components of the system, in 
particular the sensors, with due care to avoid 

damaging. 

 

 

 

 

 

 

 

Mounting the tripod

 

 

Open the HD2005.20 tripod by turning the three legs. 

 

Secure the legs to the central block of the tripod.The inclination of the legs can be adjusted 
using the various holes available. 

 

Adjust the height of the legs and tighten the locking screw. 

 

Secure the tripod firmly. The flanges of the tripod can be fixed on a floor with screws or 
on the ground with pegs.

 

 

 

 

 

 

Lightning rod installation

 

 

Fix a horizontal mast to the upper part of the 
tripod central mast (leaving the space to insert 
the HD52.3D… sensor). 

 

Fix the lightning rod, with the pointed tip up, to 
the end of the horizontal mast. The lightning rod 

must be sufficiently distant (70 cm approx.) from 
the tripod central mast in order not to interfere 

with the anemometric measurement. 

 

Connect the lightning rod to the grounding rod 

(not supplied) with a 4 AWG cable (not supplied). 

Reviews: