GHIDINI BIVIO Manual Download Page 3

GB   WARNING:

 

-Installation work must only 

be carried out by skilled, 

authorised staff. 

- Keep these instructions in 

a safe place even after 

installation. 

 

GB  (GENERAL RULES) 

- Use only lamps with power and of the type stated in the appliance’s nameplate data. 
- Warning: Before making the mains connections, during assembly, when changing a lamp or                             
  doing any other work

 

on the appliance, make sure that the power supply has been disconnected. 

 

- The appliance only operates if supplied at the voltage stated on its nameplate. 
- The appliance is suitable for installation directly on normally non-flammable surfaces. 

 

- Comply with the regulation distances from light fittings. 

 

- The appliance is in 

CLASS I : 

Connect to the electrical system ground circuit.   

 

- The appliance is 

NOT

 suitable for cascade operation. 

 

- The appliance is suitable for indoor and outdoor operation. 

 

- Use only lamps with built-in UV protection (halogen and metralide).   

 

-"The equipment must be used only if complete with protective screen(s)"

 

 

   

In the event of breakage, replace the appliance cover (

B

(SCREENS ARE NOT REPLACEABLE)

 

 

STAGE 1 

Open the appliance by unscrewing

 

the four M4 screws (

A

) and the 4 under head washers

 

provided (

B

) which fix the retainer cap (

C

)  to 

the body (

D

). 

 

 

STAGE 2 

Make 2 holes to allow insertion of 2 expansion plugs (

not supplied

) at the distances apart shown in 

FIGURE 2

Use of “Fischer” M5 metal expansion plugs with screws of at least Class 6.8 (E) is recommended. 

 

For correct application: 
• Select expansion plugs of the appropriate length, considering the load to be supported 
 (weight of appliance Max 5Kg 

+

 surface exposed to the wind 0.035 m²) and the type of substrate (concrete-brick, solid-hollow, UNI, 

etc...). 

 

STAGE 3 

Take the cable (

F

) leading out of the wall (recommended type H05RN-F section 3 x 1 mm²<HAR>) and fit it into the rubber cable gland 

(

G

), breaking the membrane. 

Take the body (

D

) and place it over the holes with the expansion plugs already fitted into the wall, and fit the 2 seals(

H

) into the seats 

provided. 

 

Start to screw in the 2 screws (

E

) (recommended size M5) , remembering to fit the 2 flat washers supplied (

I)

 between the 2 seals (

H

)   

and the 2 screws (

E

). 

Tighten (2 Nm)  the 2 screws (

E

). 

Proceed to wire the terminal block (

L

) as shown in 

FIGURE 2-3

L

    

  line 1 conductor, brown colour. 

     

  earth conductor, yellow/green colour. 

N

   

  neutral conductor, blue colour. 

Check that the cable gland (

G

) provides a perfect seal, sliding the cable (

F

) back for about a centimetre.

 

In versions with halogen lamp, silicone sheaths (1 large + 3 small) will be supplied. 
Use the large sheath (

M

) to cover the cable (

F

) and the other three  (

N

) to cover the three wires (Brown-Yellow/Green-Blue). 

If necessary, shorten all the sheaths (

M-N

) to ensure that the three wires and the cable are covered effectively 

(FIGURE 3). 

Use only lamps (

P

) with power and of the type stated in the appliance’s nameplate data.

 

WARNING: FOR THE FLUORESCENT VERSION 26W TC-TEL GX24q-3  THE MAXIMUM LENGTH MUST BE 131mm (FIGURE 4). 
 
 

 

STAGE 4 

Replace the retainer cap (

C

) with the seal (

O

) into the body 

(D

), taking care that the seal (

O)

 is not pinched or pushed out of place. 

Fix retainer cap (

C

) on the body  

(D

), tightening  (2.5 Nm) the four M4 screws (

C

), remembering to fit the 4 washers (

B

) under the heads 

of the screws (

C

). 

 

 

Summary of Contents for BIVIO

Page 1: ...BIVIO SOFFITTO IP65 Mod ISTR0017 Rev 0 11 08 www ghidini it customerservice ghidini it A FIG 1 FIG 2 FIG 3 A A A B B B B C D E E F G D H H I I L M F G N N N O P L FIG 4...

Page 2: ...a lunghezza e tipo del tassello in relazione al carico peso apparecchio Max 5Kg superficie esposta al vento 0 035 m ed al supporto calcestruzzo mattone pieno doppio UNI ecc FASE 3 Prendere il cavo F f...

Page 3: ...gth considering the load to be supported weight of appliance Max 5Kg surface exposed to the wind 0 035 m and the type of substrate concrete brick solid hollow UNI etc STAGE 3 Take the cable F leading...

Page 4: ...g dem Wind ausgesetzte Oberfl che 0 035 m und zum Tr ger Beton Voll Doppelziegel UNI usw zu w hlen PHASE 3 Das Kabel F das aus der Mauer austritt H05RN F Schnitt 3 x 1 mm HAR empfohlen nehmen und in d...

Page 5: ...longueur et le type de cheville en fonction de la charge poids appareil max 5 Kg surface expos e au vent 0 035 m et du support b ton brique pleine double UNI etc PHASE 3 Introduire le c ble F qui d pa...

Page 6: ...carga peso aparato m x 5 kg superficie expuesta al viento 0 035 m y con el soporte hormig n ladrillo lleno doble UNI etc FASE 3 Tome el cable D que sale de la pared se aconseja H05RN F sec 3 x 1 mm HA...

Page 7: ...BIVIO IP65 Mod ISTR0014 Rev 0 06 08 www ghidini it customerservice ghidini it A B C D E F G Z H I L M N O P Q R S T U V V W E Y J K FIG 1 FIG 2 FIG 3 G FIG 4 O P K X X X FIG 5 F P1 A1...

Page 8: ...i con tasselli espansione gi inseriti nel muro ed inserire negli appositi alloggiamenti le 2 guarnizioni Q Iniziare ad avvitargli le 2 viti N consigliate M5 ricordandosi di frapporre tra le 2 guarnizi...

Page 9: ...the body F and place it over the holes with the expansion plugs already fitted into the wall and fit the 2 seals Q into the seats provided Start to screw in the 2 screws N recommended size M5 remember...

Page 10: ...Mit dem Anschrauben der 2 Schrauben N M5 empfohlen beginnen und darauf achten dass die 2 mitgelieferten Flachscheiben R zwischen die 2 Dichtungen Q und die 2 Schrauben N eingesetzt werden Warnung Pr f...

Page 11: ...F sur les orifices avec les chevilles expansibles d j introduites dans le mur et introduire les 2 joints Q dans les logements pr vus cet effet Serrer les 2 vis N conseill es M5 sans oublier de mettre...

Page 12: ...correspondientes las 2 juntas Q Empiece a atornillar los 2 tornillos N se aconsejan los M5 recordando que hay que interponer entre las 2 juntas Q y los 2 tornillos N las 2 arandelas planas asignadas...

Page 13: ...BIVIO ACCESSORI IP65 Mod ISTR0015 Rev 0 07 08 www ghidini it customerservice ghidini it 2 Nm 2x 2 Nm 2x 2 5 Nm 4x 2 5 Nm 4x...