21
9. TECHNICAL DATA
9.1 Plumbing
Flow rate at 3 bar flow pressure (max.)
Affusion pipe
13.6 l/min.
Flow pressure
Minimum flow pressure
2.5 bar
Maximum flow pressure
4.0 bar
Maximum difference in flow pressure
between hot and cold water
1.0 bar
Recommended flow pressure
3.0 bar
FOOT BATH
ATT
is intrinsically protected against back flow according to DIN EN
1717*.
Permissible operating temperatures
Hot water temperature range
50-60
0
C
Thermal disinfection (3-10 min.)
75
0
C
Cold water temperature range
5-20
0
C
Anti-scald protection
40
0
C
9.2 Electric
Basin
Electric supply (voltage input) in sub-distribution board
100-240 VAC
Electric supply (voltage input) at FOOT BATH
ATT
12 VDC
Input frequency
50-60 Hz
Max. energy consumption
60 W
Output voltage
12 VDC
Output current
1.5 A
Energy consumption (sleep mode)
< 5 W
Energy consumption (operation)
20 W
Protection system
IP X4
Potential equalization
4 mm
2
Display rotary
knob
-control units
Voltage input
12 VDC
Protection system
IP X4
Diameter of drill hole/in-wall box
56 mm