X8: Switch for intermediate open
You can connect a switch for intermediate open of the door
to terminals X8.1/X8.2. You program the door positions of
intermediate open with menu item
1.6.
The switch activates this function. With an OPEN command,
the door moves to the stored door position. Only when you
deactivate this function with the switch, the door will return to
the final limit position OPEN.
You can also reach intermediate open with menu item
2.9
using
devices on X5 and X7.
▪
Install the product according to the manufacturer‘s instructions.
▪
Connect the product as shown.
▪
Activate the switch after completion of the electrical
installation with menu item
1.6.
X20/ X21: Potential-free relay contacts
You can connect more external devices, such as traffic lights,
to terminals X20.1-X20.3 and X21.1-X21.3. X20 and X21 are
potential-free relay contacts.
Damage to components!
The maximum electrical current at 24V is DC 1A. Exceeding
these values may lead to malfunctioning of the devices.