Installation Instructions
ELEKTROMAT SE 6.65-25,40 DU ER
Model: 10003346 10011
-en-
Status: 26.03.2021
Page 1: ...f Installation Instructions ELEKTROMAT SE 6 65 25 40 DU ER Model 10003346 10011 en Status 26 03 2021...
Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...
Page 3: ...connection 13 8 Emergency manual operation release 14 9 Completing commissioning inspection 16 10 Declaration of incorporation Declaration of conformity 17 Symbols Warning Potential injury or danger t...
Page 4: ...d practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe op...
Page 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...
Page 6: ...holding torque 450 Nm Maximum door weight 3000 N Supply voltage 3N 400 V Operating current 0 80 A Operating frequency 50 Hz Power factor cos 0 85 Maximum movement per hour 20 h 1 Class of protection...
Page 7: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...
Page 8: ...8 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002...
Page 9: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thor...
Page 10: ...t BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys versi...
Page 11: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...
Page 12: ...12 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...
Page 13: ...or X13 Motor plug 7 Limit switch connection S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage W3 Connect...
Page 14: ...d to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing t...
Page 15: ...15 Switch on by pulling the red handle Open or close the door by hand Switch off by pulling the green handle...
Page 16: ...ecure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good ele...
Page 17: ...ed complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The...
Page 18: ...18...
Page 19: ...19...
Page 20: ...20...