background image

1

GEZE TS4000EFS Electrohydraulic

Figure 1  Overhead Door Closer

WARNING: 

DOOR CLOSERS WITH A POWER

RATING LOWER THAN 3 OR WITH MECHANICAL
HOLD OPEN DEVICES ARE NOT SUITABLE FOR
USE WITH FIRE DOORS.

Components Checklist:

1x Closer body & cover
1x Guide Rail Assembly

2x M6 Allen Bolts
2x Plastic end caps
1x Plastic spindle cover

4x 5x55mm Self-tapping countersunk screws
2x M5x40mm Countersunk screws
4x M5x55mm Countersunk screws
2x 5x50 Self-tapping countersunk screws

Tools Required For Installation:

Flat head screwdriver
Posidrive screwdriver
Power drill
4.2mm drill bit
Template (supplied)
Pencil

10mm Spanner
5mm Allen key (supplied)
M5 Tap and Tap wrench
(steel door mounting)

User Information for Door Closers

This information must be observed. Non compliance

will absolve the manufacture from any liability. The

door closer must only be used in accordance with its

intended use; i.e. closing of side hung doors

following manual opening.

Incorrect use may cause injury

¾

Obstruction of closing process (e.g. dragging

doors, sticking weather strips/sealing rubbers, rough-

running locks)

¾

Incorrect installation and adjustment (e.g.

slamming doors)

¾

Danger of finger trap between frame and door leaf.

¾

Wrong size door closer.

¾

Closer used for other purpose than to close side

hung doors.

Maintenance:

NOTE:

¾

Maintenance to be carried out by a specialist only.

¾

Check assembly for tolerance and undue wear.

¾

Tighten any screws that may have become loose.

At least once a year:

¾

Grease moveable parts.

¾

Check operation of doors and adjust if necessary.

¾

For door closers subject to release by Electro

Mechanical and Electro Hydraulic means ensure that

local regulation are adhered to.

Installation and adjustment by specialist only

Where necessary, an additional doorstop or buffer

must be fitted to limit the maximum opening of the

door. This is of particular relevance for slide rail

closers where the opening angle may be limited by

frame. For further explanations see catalogue

preface and product information.

Door handing - DIN left / right

Stand facing the door on the hinge side / pull side. If the hinge or
pivot is to your right hand side the door is considered to be DIN
right. If the hinge or pivot is to your left hand side the door is
considered to be DIN left.

IMPORTANT WARNING:

HIGH INTERNAL PRESSURES, UNDER NO CIRCUMSTANCES
ATTEMPT TO DISMANTLE THE CLOSER.

approx. 

300

285

SECONDARY ARM

PRIMARY ARM

58

16

20

Closing speed adjuster

325

60

TS4000E BODY

48

Spindle

6

4

5

1

2

3

Size indicator

Power adjustment

TS4000E FIG1 TRANSFER LOOP

Installation Instructions

Summary of Contents for TS4000EFS

Page 1: ... frame and door leaf Wrong size door closer Closer used for other purpose than to close side hung doors Maintenance NOTE Maintenance to be carried out by a specialist only Check assembly for tolerance and undue wear Tighten any screws that may have become loose At least once a year Grease moveable parts Check operation of doors and adjust if necessary For door closers subject to release by Electro...

Page 2: ...inge side See figure 1 and 2 above The power size closing force of the TS4000E is adjusted by turning the Allen key screw situated above and to the right of the clear glass indicator tube containing a small ball bearing As the screw is turned the ball bearing will gradually move to show its power size If it doesn t appear to be moving give the indicator a gentle tap with your finger which will rel...

Page 3: ...g the closer rotate the secondary arm to approx 90 with respect to the door leaf and tighten the locking bolt Back Check The back check is a segment of the closers opening cycle with increased resistance It is factory set to come in when the door is at approx 80 Closing speed The closing speed can now be adjusted using the adjustment valve located on the front of the body of the closer Clockwise w...

Page 4: ...ermissible residual ripple 20 Duty cycle 100 Connection Insert supply voltage cable provided by others into black plastic switch box Connect cables to connector block using the positive and negative terminals as shown in fig 6 sensitive protection built into the unit that prevents operation when incorrectly connected The middle connector with brown cable is used only with a 4000E IS system ...

Reviews: