8
GEZE SecuLogic emergency exit system
à
that is suitable for use on fire protection/smoke protection doors (depending on the certification of the escape door lock)
à
IP30, suitable for use inside,
à
with a safety/retention force from outside of 5 000 N,
à
with a safety/retention force from inside of 5 000 N,
à
without time delay,
à
without blocking release,
à
with a triggering element that is mounted outside the door leaf.
3.3 Door control unit TZ 321
The GEZE SecuLogic emergency exit system - TZ 321 - with delayed emergency button - does not comply with
the requirements of EltVTR or DIN EN 13637: 2015. Use of the TZ 321 in Germany must be applied for by agree-
ment in individual case or project-related construction technique permit in accordance with the relevant
regional government building laws (national regulations).
3.4 Door control unit TZ 322
Without an additional external emergency button on the door, the GEZE SecuLogic emergency exit system - TZ 322 -
without emergency push button - does not comply with the requirements of EltVTR nor DIN EN 13637: 2015. Use of
the TZ 322 without an additional external emergency button on the door in Germany must be applied for by agree-
ment in individual case or project-related construction technique permit in accordance with the relevant regional
government building laws (national regulations).
3.5 Emergency exit sign
EltVTR requires this emergency exit sign:
EMERGENCY
PUSH-BUTTON
Only press in an emergency
DIN EN 13637:2015 requires this emergency exit sign:
The variants of TZ 320 which have been tested in accordance with DIN EN 13637:2015, receive the emergency
exit sign with the pictogram in accordance with DIN EN 13637:2015. For operation of these variants in accordance
with EltVTR in Germany, an emergency exit sign with the pictogram in accordance with EltVTR must be attached
in addition to the pictogram in accordance with DIN EN 13637:2015. The requirement and operation in accord-
ance with EltVTR are defined in the relevant regional government building ordinance.
The system components permissible in accordance with
EltVTR can be found in the current annex to the type
examination certificate:
The configurations tested to DIN EN 13637:2015 are
named in the certificate with the respective classifica-
tion key:
EltVTR
EN 13637
EltVTR
EN 13637
EltVTR
EN 13637
EltVTR
EltVTR
EN 13637