GEZE SecuLogic emergency exit system
2
Basic safety notes
To ensure personal safety, it is important to follow these safety instructions.
These instructions must be kept.
2.1 Intended use
The GEZE SecuLogic emergency exit system has been designed for controlling and monitoring electrically locked
escape routes.
2.2 Safety notes
à
Only specialists who are authorised by GEZE are permitted to carry out installation, commissioning and maintenance.
à
If unauthorised changes are made to the system, GEZE cannot be made liable in any way whatsoever for any
resulting damages.
à
GEZE does not accept any warranty for combinations with third-party products. In addition, only original GEZE
parts may be used for repair and maintenance work.
à
The connection to the mains voltage must be carried out by a qualified electrician. Perform the mains connec-
tion and protective earth connection test in accordance with VDE 0100 Part 600.
à
Sabotage-resistant cable laying in accordance with VDE 0833 (AP cables in steel hose)
à
Observe the latest versions of guidelines, standards and country-specific regulations, in particular:
à
Directive on electrical interlocking of doors in escape routes
à
DIN EN 13637: 2015 “Electrically controlled emergency exit systems for doors on escape routes”
à
DIN VDE 100-600 “Installation of low-voltage systems - Part 6 Tests”
à
DIN EN 60335-2-103 “Safety of electrical devices for home use and similar purposes, special requirements
for drives for gates, doors and windows”
à
Accident-prevention regulations, especially DGUV V1 (BGV A1) “General regulations”
à
DGUV V3 (BGV A3) “Electrical installations and equipment”
2.3 Installation information
à
The GEZE SecuLogic emergency exit system is designed exclusively for use in dry areas.
à
Cables laid in accordance with GEZE cable plan.
à
Use only the cables specified on the cable plan provided. Cables must be shielded in compliance with the wiring diagram.
à
Always use insulated wire-end ferrules for wire cores.
à
Insulate wires that are not used.
à
Secure loose cables with cable ties.
2.4 Safety-conscious working
DANGER
Danger of fatal injury due to electric shock!
When an Uninterruptible Power Supply is used, the system will still be under voltage even when
disconnected from the mains.
X
Before working on the electrical system, interrupt the power supply (mains and rechargeable
battery) and check that no voltage is present.
X
Secure workplace against unauthorised entry
2.5 Inspection of the installed system
X
Check the necessary protective earth connection to metal parts that can be touched.
X
Check the doubled/reinforced insulation of the power cables or mains connection.
2.6 Maintenance notes
X
Have doors with electric locking mechanisms on rescue routes inspected annually by an expert. This expert must
issue a certificate of the recurring inspection, which the operator must submit to the building supervisory
authority on request. The inspection can be carried out by GEZE Service within the context of a maintenance
contract or by a specialist company authorised by GEZE. The checklists in the log book must be used when the
inspection is carried out. GEZE recommends using the log book for documentation of the annual inspection.