background image

Full HD Multi-Streams Ultra-WDR Box IP Camera G-Cam/EBC-3140      Quick Guide 

 

This guide is for quick installing and connecting the Full HD Multi-Streams Ultra-WDR Box IP Camera. For more details, 
please refer to the User’s Manual of the camera in the supplied CD. 
 

Camera‘s Connectors                                                                                                                                             

                                  DC 12V/ AC 24V/ PoE 

 

No. 

Connector 

Definition 

Audio I/O   

Two-way audio transmission 

Power LED 

For power connection indication (green light) 

Default Button 

Press the button with a proper tool for at least 20 seconds to restore the system.

Auto Iris 

For auto iris lens connection 

PoE Network 

For network and PoE connections 

Network LEDs 

For network connection and activity indication 

Alarm I/O * 

Alarm Out + 

GND 

Alarm Out – 

D − 

Alarm In + 

D + 

Alarm In – 

 

 

BNC 

For analog video output (stream dependent) 

microSD Card Slot 

Insert the microSD card into the card slot to store videos and snapshots. Do 
not remove the microSD card when the camera is powered on. 

10 

Power (DC12V / AC 24V) 
 

DC 12V   

AC 24V ~ 

   

(GND) 

− 

DC 12V GND 

AC 24V ~ 

*Do 

NOT

 connect external power supply to the alarm I/O connector of the camera. 

 

NOTE:

 It is not recommended to record with the microSD card for 24/7 continuously, as it may not be able to 

support  long  term  continuous  data  read/write.  Please  contact  the  manufacturer  of  the  microSD  card  for 
information regarding the reliability and the life expectancy. 

 

Mounting C/CS Mount Lens     

 

 

 

 

 

                                                                                                               

Follow the instructions below to mount the C/CS Mount Lens to the camera. 

  Remove the plastic cover from the camera. 

  Mount the C/CS Mount Adapter to the camera. 

  Attach the lens to the adapter. 

 

Camera Cabling  

 

 

 

 

 

                                                                                                     

Please follow the instructions below for cable connections. 

 
Power Connection 

Please use a DC 12V / AC 24V power adaptor and plug it to the power connector of camera and the power outlet. 
Alternatively,  users  can  use  an  Ethernet  cable  and  connect  it to  the  RJ-45  connector  of  the  camera  and  a  Power 
Sourcing Equipment (PSE) switch. 

 

NOTE:

 If PoE is used, make sure PSE is in use in the network. 

 

 

Ethernet Cable Connection 

Connect one end of the Ethernet cable to the RJ-45 connector of the camera, and plug the other end of the cable to 
the network switch or PC. 

 

NOTE:

 In some cases, Ethernet crossover cable might be needed when connecting the camera directly to the 

PC. 
 

NOTE:

 Check the status of the link indicator and the activity indicator LEDs. If the LEDs are unlit, please check 

the LAN connection. 

 

 

Green Link Light indicates good network connection.   
Orange Activity Light flashes for network activity indication. 

 

Before Login to the Camera                                                                                                                                             

A client program will be automatically installed to the PC when connecting to the camera. Before logging in to the 
camera, please ensure downloading the ActiveX control is allowed by either changing the ActiveX controls and plug-
ins or setting Internet’s security level to default. For further details, please refer to the User’s Manual in the supplied 
CD. 

 

ActiveX Controls and Plug-ins Settings 

Internet Security Level 

Step 1:

  Start the Internet Explorer (IE). 

Step 2: 

Select  <Tools>  from  the  main  menu  of  the 

 

browser. Then click on <Internet Options>. 

Step 3: 

Click  on  the  <Security>  tab  and  select 

 

<Internet>,  and  click  on  <Custom  level>  to 

 

change ActiveX settings. 

Step 4: 

Set  “ActiveX  controls  and  plug-ins”  items  to 

 

<Prompt> or <Enable>.

 

Step 1:

  Start the Internet Explorer (IE). 

Step 2: 

Select  <Tools>  from  the  main  menu  of  the 

 

browser. Then click on <Internet Options>. 

Step 3: 

Click  on  the  <Security>  tab  and  select 

 

<Internet>. 

Step 4:

   Down the page, click <Default Level> and click 

 

on  <OK>  to  confirm  the  setting.  Close  the 

 

browser window, and open a new one later for 

 

accessing the IP camera.

 

 

Camera Login   

 

 

 

 

 

                                                                                                           

 

 

The default configuration is 

DHCP

. If no DHCP server is in network, the camera sets itself to its default IP address

 

192.168.0.250

. You find the camera via the 

Device Searching Tool

 (on the CD). Therefore, to access the camera for 

the first time, please set the IP address of the PC as: 192.168.0.XXX; for example: 

 

IP Address:    192.168.0.100 
Subnet Mask: 255.255.255.0 

 

Login ID and Password 

  Key in the camera’s IP address in the URL bar of the web browser window and hit on “Enter”.   

  Enter the default username (

root

) and password (

admin

) in the prompt request dialogue. Note that username is 

case sensitive. 

 

Install the ActiveX Control 

  After connecting to the camera, the request for installing the ActiveX control will appear just below the URL bar. 

  Right click on the information bar, and then click on <Install ActiveX Control…> to permit ActiveX control installation. 

  In the pop-up security warning window, click on <Install> to start downloading the DCViewer software on the PC. 