background image

GESIPA Blindniettechnik GmbH

Nordendstraße 13-39

64546 Mörfelden-Walldorf

Germany

GBM 95

T +49 (0) 6105 962 0

F +49 (0) 6105 962 287

[email protected]

www.gesipa.com

Summary of Contents for GBM 95

Page 1: ...GESIPA Blindniettechnik GmbH Nordendstraße 13 39 64546 Mörfelden Walldorf Germany GBM 95 T 49 0 6105 962 0 F 49 0 6105 962 287 info gesipa com www gesipa com ...

Page 2: ......

Page 3: ......

Page 4: ... 7557 54 143 5204 55 143 4236 56 144 5292 57 143 4237 1 143 5213 M3 143 5214 M4 8 32 143 5215 M5 10 32 143 5216 M6 143 5217 M8 5 16 18 143 5218 M10 3 8 16 143 5148 1 4 20 2 143 5207 M3 143 5208 M4 143 5209 M5 143 5210 M6 143 5211 M8 143 5212 M10 143 5149 8 32 143 5143 10 32 143 5144 1 4 20 143 5150 5 16 18 143 5145 3 8 16 3 143 5185 4 143 5220 5 145 7574 6 143 4232 7 145 7560 8 145 6754 9 144 5265...

Page 5: ... mandrel length X 17 6 2 Adjustment of stroke Y 18 6 3 Threading on and setting of a blind rivet nut 19 6 4 Change of threaded mandrel 20 6 5 Change of unthreading time 20 7 Maintenance and service 20 8 Repairs 21 9 Environmental notes 21 10 Troubleshooting 21 10 1 Rivet nut is not threading on 21 10 2 Set rivet nut is loose 21 10 3 Threaded mandrel is not unthreading 21 11 Warranty 22 12 Conformi...

Page 6: ...es Personal safety equipment such as protective clothing protective gloves helmet nonslip shoes and hea ring protection are recommended in order to safeguard against accidents Keep long hair or loose clothing away from the tool during operation or when servicing Repairs should be carried out by trained personnel only If in doubt return the tool to the supplier Used hydraulic oil must be disposed o...

Page 7: ...fore starting carefully read and follow operating instructions 6 1 Adjustment of mandrel length X Disconnect tool from compressed air to unlock the threaded mandrel In case of standard blind rivets nuts a the protruding part of the threaded mandrel 2 must be as long as the whole blind rivet nut see drawing 1 and is hand adjusted by turning the mandrel either in or out In case of closed end rivet n...

Page 8: ...M4 1 2 M5 1 5 2 5 M6 2 5 3 5 M8 3 5 4 5 M10 3 5 4 5 Loosen lock nut 3 drawing 1 Adjust stroke Y by turning in or out the nosepiece 1 Stroke Y has to be adjusted to min to be locked tightened and then the rivet nut has to be set If the blind rivet nut does not form a proper sealing head as shown in drawing 2 the stro ke Y must be increased step by step Afters stroke adjustment the lock nut 3 has to...

Page 9: ...Release button 35 The threaded mandrel 2 is threaded off automatically Drawing 3 Attention In order to avoid upsetting smaller or thin wall type blind rivet nuts during the threa ding process disconnect tool and increase the threaded mandrel protusion to a length such that the rivet nut does not thread on flush against the nosepiece Adjust setting stroke see paragraph 6 2 Important If the threaded...

Page 10: ...ed mandrel 2 by turning backward and forward until mandrel releases Screw in new threaded mandrel Screw in corresponding nosepiece 1 with lock nut 3 Adjust setting stroke Y and length of threaded mandrel X see paragraphs 6 1 and 6 2 6 5 Change of unthreading time The adjusting screw at the edge of the handle near the air connection can be reached with enclosed ball headed screw driver SW 2 5 mm se...

Page 11: ...lic oil must be disposed of in accordance with recycling regulations 10 Troubleshooting 10 1 Rivet nut is not threading on Cause Solution Faulty rivet nut thread Use new rivet nut Faulty mandrel thread Exchange threaded mandrel see para graph 6 4 Hold rivet nut tightly when threading out 10 2 Set rivet nut is loose Cause Solution Setting stroke Y too short Adjust to larger stroke see paragraph 6 2...

Page 12: ... put on the market complies with applicable fundamental health and safety requirements stipulated in EU directives Tool modifications made without our authori sation shall render this declaration void The safety information in the product documentation provided must be observed This document must be retained GBM 95 DIN EN ISO 12100 2011 DIN EN ISO 11148 1 2012 DIN EN 82079 1 2013 Authorised docume...

Page 13: ...08 2017 1431959 ...